Siemens 4EU3622-7DA00-0AA0 Commutating Choke, 355A, 750V, 0.

MPN4EU3622-7DA00-0AA0

Siemens 4EU3622-7DA00-0AA0 commutating choke for converters, 3-phase, 750V AC, 355A max, 0.12mH, IP00, thermal class H.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EU3622-7DA00-0AA0 — Inductance & Impedance
ParameterValue
Rated inductance0.00012H
Relative inductive voltage drop4%

Identification

4EU3622-7DA00-0AA0 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter

Electrical

4EU3622-7DA00-0AA0 — Electrical
ParameterValue
Rated operating voltage750, 750V
Number of phases3
Rated current (DC)435A
Voltage typeAC
Rated operating frequency60 ... 50Hz
Peak current444A

Losses & Thermal

4EU3622-7DA00-0AA0 — Losses & Thermal
ParameterValue
Power loss, coil (W)320W
Power loss, iron core (W)180W
Rated ambient temperature40°C

Approvals

4EU3622-7DA00-0AA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H

Mechanical

4EU3622-7DA00-0AA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.321m
Width0.35m
Depth0.227m

Product details

The Siemens 4EU3622-7DA00-0AA0 is a 3-phase commutating choke (drossel) for converter applications, rated for 750 V AC operating voltage and a maximum continuous current of 355 A at 50 Hz. The rated inductance is 0.12 mH, with a relative inductive voltage drop of 4% at rated current and frequency. It's a mature-line part, so availability is steady through independent distribution — quoted to order against an RFQ.

What the ratings mean for fit

The 355 A maximum at 50 Hz (319.5 A rated continuous, 444 A peak) tells you this choke is sized for a converter feeding a motor or load drawing around 320 A RMS in steady state — think large pumps, compressors, or conveyor drives on 400–690 V class systems. The 0.12 mH inductance and 4% voltage drop are matched to the converter's commutation needs; swapping in a choke with significantly different inductance changes the DC-link ripple and can stress the IGBTs.

Where it goes in the panel

IP00 means it's open-frame — no enclosure, so it mounts inside a cabinet. The flat-type terminal connections accept busbar or cable lugs. Dimensions are 0.35 m wide × 0.321 m tall × 0.227 m deep.

Thermal and environmental limits

Rated for 40 °C ambient with thermal class H insulation — that's a 180 °C temperature class per IEC 60085, meaning the winding can handle sustained hot-spot temperatures up to 180 °C. The 60 to 50 Hz operating frequency range covers both 50 Hz and 60 Hz grids; the current ratings hold at either frequency.