Skip to main content
Siemens 4EU3622-8AA00-0AA0 — Line/Load Reactors

Siemens 4EU3622-8AA00-0AA0 Commutating Choke, 450A, 500V, 3-

MPN4EU3622-8AA00-0AA0

Siemens 4EU3622-8AA00-0AA0 commutating choke for converter, 3-phase, 450 A rated, 500 V AC, 50 Hz, IP00, thermal class H.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EU3622-8AA00-0AA0 — Inductance & Impedance
ParameterValue
Rated inductance0.000073H
Relative inductive voltage drop4%

Identification

4EU3622-8AA00-0AA0 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter

Electrical

4EU3622-8AA00-0AA0 — Electrical
ParameterValue
Rated operating voltage500V
Number of phases3
Rated current (DC)612.7A
Voltage typeAC
Rated operating frequency50Hz

Losses & Thermal

4EU3622-8AA00-0AA0 — Losses & Thermal
ParameterValue
Power loss, coil (W)280W
Power loss, iron core (W)200W
Rated ambient temperature40°C

Approvals

4EU3622-8AA00-0AA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H

Mechanical

4EU3622-8AA00-0AA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.321m
Width0.35m
Depth0.227m

Product details

What it is and what it does

The Siemens 4EU3622-8AA00-0AA0 is a commutating choke (line reactor) designed for use with power converters. It smooths current commutation and limits di/dt and peak fault currents on the AC side of a 3-phase converter bridge. Rated for 450 A continuous at 500 V AC, 50 Hz, with a maximum current of 500 A and a DC-side rating of 612.7 A, it handles the full converter throughput in a medium-power drive or rectifier line-up. The 4% relative inductive voltage drop (at rated current, voltage, and frequency) tells you the impedance the choke inserts into the line — enough to reduce harmonic distortion and protect the converter's semiconductors from switching transients, without dropping excessive voltage under load. Inductance is 0.000073 H (73 µH), and total power loss splits into 280 W in the coil and 200 W in the iron core at rated conditions — 480 W total heat to manage inside the enclosure.

Deployment context and mounting

This is an open-frame component with IP00 protection — no enclosure, no ingress sealing. It is intended for installation inside a panel or cabinet where the ambient stays at or below 40 °C and where personnel cannot contact live parts. The main circuit connects via flat-type terminals (busbar or cable lug), so plan for bolted connections, not spring clamps. Physical footprint: 0.35 m wide, 0.321 m tall, 0.227 m deep — roughly 14 by 13 by 9 inches. That is a substantial block; verify the gland plate and backpanel clearance before committing the layout.

Thermal class and lifecycle

Thermal class H per IEC 60085 means the insulation system withstands a continuous hot-spot temperature of 180 °C. That gives headroom for the 480 W total loss in a warm cabinet, but the rated ambient is 40 °C — derate if your enclosure ambient runs higher. Lifecycle status is listed as mature. That typically means the design is stable and not subject to short-term obsolescence, but it is not a current-promotion item. Availability is confirmed at time of RFQ through independent distribution channels.

Frequently asked questions

Where can I buy 4EU3622-8AA00-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of 4EU3622-8AA00-0AA0?

It is a 3-phase commutating choke rated 450 A continuous at 500 V AC, 50 Hz, with a maximum current of 500 A and a DC-side rating of 612.7 A. Inductance is 73 µH with a 4% voltage drop at rated conditions.

MPN