Siemens 4EU3652-4UA00-1BA0 — Line/Load Reactors

Siemens 4EU3652-4UA00-1BA0 Mains Choke, 910A, 500V, 3-Phase

MPN4EU3652-4UA00-1BA0

Siemens SENTRON 4EU3652-4UA00-1BA0 mains choke (line reactor) for frequency converters, 3-phase, 500V AC, 910A max / 819A rated, 0.02 mH, 2% voltage drop, IP00, flat-type terminals, Class H, EN 61558-2-20, UL/CSA recognized.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EU3652-4UA00-1BA0 — Inductance & Impedance
ParameterValue
Rated inductance0.00002H
Relative inductive voltage drop2%
4EU3652-4UA00-1BA0 — Identification
ParameterValue
Product designationNetzdrossel f. FU
4EU3652-4UA00-1BA0 — Electrical
ParameterValue
Rated operating voltage500V
Number of phases3
Voltage typeAC
Rated operating frequency50Hz
4EU3652-4UA00-1BA0 — Losses & Thermal
ParameterValue
Power loss, coil (W)394W
Power loss, iron core (W)130W
Rated ambient temperature40°C
4EU3652-4UA00-1BA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU3652-4UA00-1BA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.321m
Width0.35m
Depth0.237m

Product details

The Siemens 4EU3652-4UA00-1BA0 is a mains choke (line reactor) designed for installation ahead of a variable-frequency drive (VFD) — it limits harmonic distortion, reduces peak currents, and protects the drive's DC bus from line transients. Rated for 3-phase, 500V AC, 50 Hz, it carries a maximum current of 910A and a rated continuous current of 819A (cites:,).

The 910A maximum / 819A rated current tells you this choke is sized for a high-power VFD — think large conveyors, pumps, or compressor trains in the 400–500 kW range on 500V supply. The 0.02 mH inductance (20 µH) is low, which is correct for a high-current line reactor; the 2% voltage drop confirms it's a light-duty filter that won't starve the drive of voltage (cites:,). IP00 means it's an open-frame component — no enclosure, no finger-safe cover. The 394W coil loss plus 130W iron loss (524W total at full load) must be dissipated; factor that into your panel thermal budget (cites:,).

Dimensions are 0.35 m wide × 0.321 m tall × 0.237 m deep — roughly 14 × 12.6 × 9.3 inches — so it occupies a significant footprint in the cabinet (cites:,). Main circuit connections use flat-type terminals (bus-bar compatible), not screw clamps; plan for bolted lugs or bus-bar stubs (cites:). Listed to EN 61558-2-20 (safety of transformers, reactors, and power supply units) and UL/CSA recognized (cites:).