Skip to main content
Siemens 4EU3652-4UC00-0AA0 — Line/Load Reactors

Siemens 4EU3652-4UC00-0AA0 Mains Choke, 560 A, 690 V AC

MPN4EU3652-4UC00-0AA0

Siemens SENTRON 4EU3652-4UC00-0AA0 mains choke for frequency converters, 3-phase, 690 V AC, 560 A max / 504 A rated, 0.045 mH, IP00, flat-type terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

4EU3652-4UC00-0AA0 — Inductance & Impedance
ParameterValue
Rated inductance0.000045H
Relative inductive voltage drop2%
4EU3652-4UC00-0AA0 — Identification
ParameterValue
Product designationNetzdrossel f. FU
4EU3652-4UC00-0AA0 — Electrical
ParameterValue
Rated operating voltage690V
Number of phases3
Voltage typeAC
Rated operating frequency50Hz
4EU3652-4UC00-0AA0 — Losses & Thermal
ParameterValue
Power loss, coil (W)300W
Power loss, iron core (W)138W
Rated ambient temperature40°C
4EU3652-4UC00-0AA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU3652-4UC00-0AA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.321m
Width0.35m
Depth0.237m
4EU3652-4UC00-0AA0 — Other specifications
ParameterValue
Rated value504A

Product details

Mains choke for frequency converter drives

It smooths current harmonics and limits inrush, protecting both the drive and upstream components. Rated for 504 A continuous with a 560 A maximum, at 690 V AC and 50 Hz. The 0.000045 H inductance and 2 % relative inductive voltage drop are tuned for typical drive-line harmonic suppression. Thermal class H means the insulation system withstands the hot-spot temperature appropriate for the 300 W coil loss plus 138 W iron core loss at 40 °C ambient.

The 560 A maximum rating sets the upper bound for the connected drive's input current — do not exceed this on continuous duty. The 504 A rated value is the design point for thermal and harmonic performance. Verify lug width against the 0.35 m width and 0.321 m height for panel layout.

Frequently asked questions

Will 4EU3652-4UC00-0AA0 fit in a panel designed for a motor circuit breaker like 3RV6011-0CA10?

No — the 4EU3652-4UC00-0AA0 is a large mains choke (0.35 m wide, 0.321 m tall, 0.237 m deep) with flat-type terminals, while the 3RV6011-0CA10 is a compact 45 mm wide DIN-rail motor circuit breaker. They serve different functions and have completely different footprints.

MPN
4EU3652-4UC00-0AA0