4EU3922-0AD00-0A specifications
ParameterValue
Type of voltageAC
Type of electrical connection for main current circuitflat connector
Operating voltage rated value400V
Relative inductive drop in voltage on the measurement level current, voltage and frequency3.04%
Operating frequency rated value60 ... 50Hz
Phase number3
Ambient temperature rated value40°C
Depth0.229m
Width0.41m
Height0.385m
Thermal class acc. to IEC 60085H
Rated value900A
Protection class IPIP00
Inductivity rated value0.000022H

Product details

The Siemens 4EU3922-0AD00-0A is a three-phase commutating choke (commutation reactor) for converter applications — it limits the rate of rise of fault current and reduces harmonic distortion on the DC link of a variable-frequency drive or rectifier. Rated at 900 A continuous with a 1000 A maximum, it operates at 400 V AC, 50/60 Hz, with an inductance of 0.022 mH and a relative inductive voltage drop of 3.04% at rated conditions.

The 1000 A maximum / 900 A rated current tells you this choke is sized for a high-power drive line — think large pumps, compressors, or conveyor systems drawing 900 A continuous. The 3.04% voltage drop at rated current is typical for a line-side choke; it smooths the DC bus ripple and limits peak currents during commutation. Thermal class H (IEC 60085) means the insulation system withstands 180 °C hot-spot temperature — essential in a high-current, enclosed panel where ambient can hit 40 °C. IP00 protection means it is an open-frame component: it must be installed inside a cabinet with proper clearance and ventilation; not for standalone outdoor or washdown use.

This choke mounts into a panel or drive cabinet via its flat-type terminals (main circuit connection) — no DIN-rail clip, no screw-on base. The 0.229 m depth, 0.41 m width, and 0.385 m height mean it needs a dedicated footprint in the enclosure; allow for air circulation around the core, especially given the 40 °C ambient rating and class H thermal margin. The flat connectors are sized for bolted bus-bar or cable-lug terminations typical of high-current power sections.

Frequently asked questions

Who supplies 4EU3922-0AD00-0A and how is it quoted for volume purchases?

This part is sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is listed here, but a request for quote (RFQ) will return a firm offer.

What compliance documentation does this part carry?

The choke is designed to EN 61558-2-20 (safety of transformers, reactors, and power supply units) and carries thermal class H per IEC 60085. No specific UL, CSA, or RoHS certificate is listed in the record, but the EN standard is the governing European safety norm for this product class.

MPN