Skip to main content
Siemens 4EU3951-3UB00-0A — Line/Load Reactors

Siemens 4EU3951-3UB00-0A Mains Choke, 560A, 500V AC, 50Hz

MPN4EU3951-3UB00-0A

Siemens SENTRON 4EU3951-3UB00-0A mains choke for frequency converters, 3-phase, 500V AC, 50Hz, 560A max / 504A rated, 65µH, 4% voltage drop, IP00, flat-type terminals, Class H insulation.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EU3951-3UB00-0A — Inductance & Impedance
ParameterValue
Rated inductance0.000065H
Relative inductive voltage drop4%
4EU3951-3UB00-0A — Identification
ParameterValue
Product designationNetzdrossel f. FU
4EU3951-3UB00-0A — Electrical
ParameterValue
Rated operating voltage500V
Number of phases3
Voltage typeAC
Rated operating frequency50Hz
4EU3951-3UB00-0A — Losses & Thermal
ParameterValue
Power loss, coil (W)540W
Power loss, iron core (W)190W
Rated ambient temperature40°C
4EU3951-3UB00-0A — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU3951-3UB00-0A — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.385m
Width0.41m
Depth0.229m

Product details

The Siemens 4EU3951-3UB00-0A is a three-phase mains choke (Netzdrossel f. FU) designed for the input side of a frequency converter. It smooths line current, reduces harmonic distortion, and limits inrush current peaks that would otherwise stress the drive's DC bus capacitors. Rated for 504 A continuous with a 560 A maximum, it handles the full-load current of a large drive without saturating. The 500 V AC operating voltage and 50 Hz line frequency match standard European industrial mains. The 65 µH inductance and 4 % relative inductive voltage drop are the key sizing parameters — they determine how much line impedance the choke adds, which governs the harmonic attenuation and the voltage sag the drive sees under load.

Thermal and construction details

Total power loss is 730 W — 540 W in the coil and 190 W in the iron core — all dissipated as heat. Class H insulation (180 °C thermal class per IEC 60085) means the winding can run hot without degrading; still, the panel builder needs to account for that heat load in the enclosure ventilation. IP00 protection class means it is an open-frame component — no housing, no splash protection. Main circuit connections are flat-type terminals (bus-bar style), not screw clamps. That means the installer needs a bus-bar or a flat-cable lug kit — standard ring terminals won't fit.

Because it is a mature, high-current line reactor with UL/CSA recognition per EN 61558-2-20, it is still widely specified for drive panels that need a listed input choke.

Physical footprint

Dimensions are 0.229 m deep, 0.41 m wide, and 0.385 m tall — roughly 9 by 16 by 15 inches. That is a substantial block; verify the cabinet depth and backplate space before committing the panel layout.

Frequently asked questions

What are the key electrical ratings for 4EU3951-3UB00-0A?

560 A maximum, 504 A rated continuous, 500 V AC, 50 Hz, 65 µH inductance, 4 % voltage drop. Total power loss is 730 W. Class H insulation (180 °C).

What approvals does 4EU3951-3UB00-0A carry?

UL/CSA recognized per EN 61558-2-20, the standard for chokes and reactors. No RoHS or REACH date is listed in the available documentation.

Where can I buy 4EU3951-3UB00-0A and what is the lead time?

We source this part through independent distribution and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here.

Will 4EU3951-3UB00-0A drop into a panel specified for 3RV6011-0CA10?

No — those are completely different component classes. 3RV6011-0CA10 is a SIRIUS motor-protective circuit breaker (0.25 A, DIN-rail mount, 45 mm wide). 4EU3951-3UB00-0A is a 500 A mains choke with flat-type terminals, 410 mm wide, open-frame. No physical or electrical compatibility.