Skip to main content
Siemens 4EU3951-6UB00-0A — Line/Load Reactors

Siemens 4EU3951-6UB00-0A Mains Choke, 1120 A, 690 V AC, 50 H

MPN4EU3951-6UB00-0A

Siemens 4EU3951-6UB00-0A mains choke for variable-frequency drives, 3-phase, 690 V AC, 50 Hz, rated current 1008 A, max 1120 A, 0.022 mH, IP00, thermal class H, flat-type terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EU3951-6UB00-0A — Inductance & Impedance
ParameterValue
Rated inductance0.000022H
Relative inductive voltage drop2%
4EU3951-6UB00-0A — Identification
ParameterValue
Product designationNetzdrossel f. FU
4EU3951-6UB00-0A — Electrical
ParameterValue
Rated operating voltage690V
Number of phases3
Voltage typeAC
Rated operating frequency50Hz
4EU3951-6UB00-0A — Losses & Thermal
ParameterValue
Power loss, coil (W)540W
Power loss, iron core (W)190W
Rated ambient temperature40°C
4EU3951-6UB00-0A — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU3951-6UB00-0A — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.385m
Width0.41m
Depth0.229m

Product details

What it is and what it does

The Siemens 4EU3951-6UB00-0A is a three-phase mains choke (line reactor) designed for the input side of a variable-frequency drive. It smooths current harmonics, limits inrush, and provides a degree of protection against line-side transients — the 2 % relative inductive voltage drop at rated current and frequency is the key figure that governs its filtering effect. Rated for 1008 A continuous (1120 A maximum) at 690 V AC, 50 Hz, with an inductance of 0.022 mH. The 540 W coil loss and 190 W iron-core loss at rated conditions give a total self-heating of 730 W — that heat must be managed in the enclosure, especially given the IP00 open-frame construction. Thermal class H (180 °C) insulation per IEC 60085 means the winding can handle sustained hot-spot temperatures up to that class limit, which is typical for drive-duty chokes that see high ambient plus self-heating.

Mounting and integration

The choke measures 0.41 m wide by 0.385 m tall by 0.229 m deep — a substantial footprint. IP00 means it has no enclosure; it must be mounted inside a panel or cabinet that provides the required touch protection and cooling airflow. The flat-type terminals on the main circuit accept busbar or large cable lugs; plan for adequate bending radius and clearance around the connections.

Frequently asked questions

What compliance documentation does this brand provide for 4EU3951-6UB00-0A?

The choke carries UL and CSA recognition per EN 61558-2-20. The manufacturer typically provides a declaration of conformity for CE marking; RoHS and REACH compliance documentation should be available on request.

MPN
4EU3951-6UB00-0A