Skip to main content
Siemens 4EU4351-1UB00-0A — Line/Load Reactors

Siemens 4EU4351-1UB00-0A Mains Choke, 1260 A, 690 V, 50 Hz

MPN4EU4351-1UB00-0A

Siemens 4EU4351-1UB00-0A mains choke (line reactor) for variable-frequency drives, 3-phase, 690 V AC, 1260 A rated current, 50 Hz, 2 % voltage drop, IP00, UL/CSA recognized.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EU4351-1UB00-0A — Inductance & Impedance
ParameterValue
Rated inductance0.000018H
Relative inductive voltage drop2%
4EU4351-1UB00-0A — Identification
ParameterValue
Product designationNetzdrossel f. FU
4EU4351-1UB00-0A — Electrical
ParameterValue
Rated operating voltage690V
Number of phases3
Voltage typeAC
Rated operating frequency50Hz
4EU4351-1UB00-0A — Losses & Thermal
ParameterValue
Power loss, coil (W)700W
Power loss, iron core (W)250W
Rated ambient temperature40°C
4EU4351-1UB00-0A — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU4351-1UB00-0A — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.435m
Width0.46m
Depth0.265m

Product details

This is an open-frame (IP00) component — no enclosure, no DIN-rail clip. It measures 0.46 m wide by 0.435 m tall by 0.265 m deep. The main circuit connects via flat-type terminals, so you'll need busbar or cable lugs sized for the 1260 A continuous path. Plan for free-air mounting inside a cabinet with forced ventilation; the coil alone dissipates 700 W, plus 250 W from the iron core, for a total of 950 W of heat that has to leave the enclosure.

Thermal class and approvals

The winding insulation is rated thermal class H per IEC 60085, which means a 180 °C continuous hot-spot limit — generous headroom for a 40 °C ambient rating. The part carries UL and CSA recognition per the description line, and is designed to EN 61558-2-20.

Frequently asked questions

What are the key ratings for 4EU4351-1UB00-0A?

Rated current 1260 A, maximum current 1400 A, rated voltage 690 V AC, 50 Hz, 2 % voltage drop, inductance 18 µH.

Where can I buy 4EU4351-1UB00-0A?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does 4EU4351-1UB00-0A carry?

The part is UL and CSA recognized, and designed to EN 61558-2-20. The insulation system is thermal class H per IEC 60085.

MPN
4EU4351-1UB00-0A