Siemens SIDAC output reactor, 4EU4521-0BS00-4B, 3-phase, 480 V, 120 A max, 8 kHz switching frequency, 0.2 mH, IP00.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EU4521-0BS00-4B — Inductance & Impedance
ParameterValue
Rated inductance0.0002H
4EU4521-0BS00-4B — Identification
ParameterValue
Product designationoutput reactor
4EU4521-0BS00-4B — Electrical
ParameterValue
Number of phases3
Voltage typeAC
4EU4521-0BS00-4B — Losses & Thermal
ParameterValue
Power loss, coil (W)184W
Power loss, iron core (W)445W
Rated ambient temperature40°C
4EU4521-0BS00-4B — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU4521-0BS00-4B — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.43m
Width0.46m
Depth0.29m

Product details

The Siemens SIDAC 4EU4521-0BS00-4B is a 3-phase output reactor rated for 480 V AC with a maximum continuous current of 120 A and an inductance of 0.0002 H. It sits between a drive and motor, smoothing PWM edges and limiting voltage rise rate on long cable runs.

The 8 kHz switching frequency rating matches typical IGBT carrier frequencies. The 0.0002 H inductance and 76% impedance limit motor-terminal overvoltage on long cable runs. IP00 means it's an open-frame component — no drip shield, no enclosure. It belongs in a ventilated cabinet, not on the plant floor exposed to washdown or dust. The Class H insulation (180 °C thermal class per IEC 60085) gives headroom for the 184 W coil loss and 445 W iron-core loss at the rated 40 °C ambient. Flat-type terminals for the main circuit mean the connection is a bus-bar or heavy-crimp lug interface, not a spring-cage or screw-clamp. Factor that into your panel wiring plan — you'll need the right crimp tool and clearance for the lug stack height.

Frequently asked questions

How do I get current pricing and availability for 4EU4521-0BS00-4B?

Submit an RFQ against this part number. We source it through independent distribution and confirm current pricing and lead time at quote — no automated stock figure here, because the supply channel for a mature reactor like this varies by region and quantity.

Will 4EU4521-0BS00-4B drop into a panel specified around 5SL3232-6MB?