Skip to main content
Siemens 4EU4521-0CC10-0B — Line/Load Reactors

Siemens 4EU4521-0CC10-0B Commutating Choke, 1059 A, 1060 V,

MPN4EU4521-0CC10-0B

Siemens 4EU4521-0CC10-0B commutating choke for converter, 3-phase, 1059 A rated, 1060 V AC, 50 Hz, 45 µH, IP00, flat-type terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EU4521-0CC10-0B — Inductance & Impedance
ParameterValue
Rated inductance0.000045H
Relative inductive voltage drop2.96%
4EU4521-0CC10-0B — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter
4EU4521-0CC10-0B — Electrical
ParameterValue
Rated operating voltage1 060V
Number of phases3
Voltage typeAC
Rated operating frequency50Hz
4EU4521-0CC10-0B — Losses & Thermal
ParameterValue
Power loss, coil (W)660W
Power loss, iron core (W)350W
Rated ambient temperature40°C
4EU4521-0CC10-0B — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU4521-0CC10-0B — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.435m
Width0.46m
Depth0.293m

Product details

The Siemens 4EU4521-0CC10-0B is a three-phase commutating choke for converter applications, rated 1059 A at 1060 V AC, 50 Hz. Its 45 µH inductance limits di/dt and reduces commutation notches on the line side of a thyristor or IGBT converter bridge. This is a high-current, open-frame (IP00) component sized for large drives or power converters. The 1059 A continuous rating and 1060 V insulation class put it in the heavy-industrial band — think mill drives, marine propulsion converters, or large pump/compressor VFD line-ups. Total power loss at rated load sums to 1010 W (660 W coil + 350 W iron core), which means forced-air cooling or a dedicated ventilation slot in the enclosure is mandatory. The thermal class H winding (IEC 60085) allows a 180 °C hot-spot limit, but the 40 °C ambient rating is the design point — derate above that.

Sizing and integration notes

Physical envelope: 0.46 m wide × 0.435 m high × 0.293 m deep. Plan for floor-mount or heavy steel sub-panel. Termination is via flat-type connectors, so the mating busbars or cable lugs need to match a flat interface. No screw-clamp or spring-cage option — budget for custom busbar fabrication if your panel is built around ring terminals. The relative inductive voltage drop is 2.96 % at rated current, frequency, and voltage. That figure tells you the choke's impedance at line frequency — useful for calculating the actual voltage available at the converter input under load.

Frequently asked questions

What is the physical size of 4EU4521-0CC10-0B?

Width 0.46 m, height 0.435 m, depth 0.293 m. This is a floor-mount or heavy sub-panel component, not DIN-rail mountable.

MPN
4EU4521-0CC10-0B