Siemens 4EU4551-5UA00 — Line/Load Reactors

Siemens 4EU4551-5UA00 Mains Choke, 1120 A, 3-Phase, 500 V

MPN4EU4551-5UA00

Siemens 4EU4551-5UA00, Netzdrossel f. FU, 3-phase mains choke, rated 1120 A, 500 V AC, 50/60 Hz, IP00, flat-type terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

4EU4551-5UA00 specifications
ParameterValue
Type of voltageAC
Type of electrical connection for main current circuitflat connector
Operating voltage rated value500, 500V
Relative inductive drop in voltage on the measurement level current, voltage and frequency4%
Power loss [W] of the coil700W
Power loss [W] of the iron core400W
Operating frequency rated value60 ... 50Hz
Phase number3
Ambient temperature rated value40°C
Depth0.293m
Width0.46m
Height0.435m
Thermal class acc. to IEC 60085H
Rated value1 120A
Protection class IPIP00
Inductivity rated value0.000032H

Product details

The Siemens 4EU4551-5UA00 is a 3-phase mains choke (Netzdrossel f. FU) rated for 1120 A continuous at 500 V AC, 50/60 Hz. It is designed for the line side of a frequency converter drive to attenuate harmonics, limit inrush current, and provide some protection against line notching. The IP00 enclosure means it is an open-frame component intended for mounting inside a cabinet or panel — not for standalone outdoor or washdown duty. Thermal class H insulation (IEC 60085) allows a 40 °C ambient with a 700 W coil loss and 400 W iron core loss, so forced ventilation or adequate cabinet airflow is expected at full load.

The 1120 A rating is the maximum thermal current (Ithmax) at the rated frequency — this is the continuous current the choke can carry without exceeding its thermal class H limits at 40 °C ambient. For a drive application, size the choke so the drive's input current does not exceed this figure; a 4% relative inductive voltage drop (UK=4%) at rated current is typical for a line reactor intended to reduce harmonic distortion. The 0.000032 H (32 µH) inductance value is the per-phase inductance at rated current and frequency. The flat-type terminals are sized for high-current busbar or cable lug connections — not spring-cage or screw-clamp terminations. Verify the terminal hole pattern and busbar spacing against your panel layout before ordering.

MPN
4EU4551-5UA00