Skip to main content
Siemens 4EU5021-0AB10 — Line/Load Reactors

4EU5021-0AB10 Siemens Commutating Choke, 1800 A, 750 V AC, 5

MPN4EU5021-0AB10

Siemens 4EU5021-0AB10 commutating choke for converter, 3-phase, 750 V AC, 1800 A, 50 Hz, 24 µH, IP00, flat-type terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EU5021-0AB10 — Inductance & Impedance
ParameterValue
Rated inductance0.000024H
Relative inductive voltage drop4%
4EU5021-0AB10 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter
4EU5021-0AB10 — Electrical
ParameterValue
Rated operating voltage750V
Number of phases3
Rated current (DC)2 205.8A
Voltage typeAC
Rated operating frequency50Hz
4EU5021-0AB10 — Losses & Thermal
ParameterValue
Power loss, coil (W)1 000W
Power loss, iron core (W)460W
Rated ambient temperature40°C
4EU5021-0AB10 — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU5021-0AB10 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.565m
Width0.518m
Depth0.318m

Product details

The Siemens 4EU5021-0AB10 is a three-phase commutating choke (Kommut.-Drossel f. Stromrichter) designed for line-side or DC-link use in converter and drive systems. It carries a continuous rated current of 1800 A at 750 V AC, 50 Hz, with an inductance of 24 µH and a relative inductive voltage drop of 4 % at rated conditions. The IP00 open-frame construction means it mounts inside a cabinet or enclosure — no touch protection on the choke itself, so the panel must provide the guarding.

The 1800 A rating (both maximum and rated value) sets the thermal current-carrying capability at 40 °C ambient. That figure governs the busbar or cable sizing upstream and downstream — the choke itself won't be the bottleneck at that current level. The 750 V AC operating voltage matches common 690 V line-to-line systems with headroom; verify the converter's DC-link voltage does not exceed this rating. Total power loss sums to 1460 W (1000 W in the coil, 460 W in the iron core). That heat must be removed from the enclosure — forced ventilation or a derated fill factor in a sealed cabinet. The thermal class H insulation (IEC 60085) allows a 180 °C hot-spot temperature, so the choke can run hot, but the surrounding components may not. The flat-type terminals (flat connector) are sized for bolted busbar connections — not wire lugs or spring cages. Plan for a busbar interface rather than cable tails.

Integration notes

Physical footprint: 0.518 m wide × 0.318 m deep × 0.565 m tall. That is a substantial component — roughly half a meter each way — so verify the enclosure depth and backplate space before committing. The IP00 rating means no integrated enclosure; mount it on a non-flammable, grounded panel with clearance to adjacent live parts per IEC 61439-1.

MPN
4EU5021-0AB10