Skip to main content
Siemens 5SJ4104-7HG41 — 1-Pole MCB (DIN Rail)

Siemens 5SJ4104-7HG41 SENTRON MCB, 1P C-curve, 10 kA

MPN5SJ4104-7HG41
Active

Siemens SENTRON 5SJ4 miniature circuit breaker, 1-pole, C-curve, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 400 V AC, 60 V DC, 18 mm wide, DIN-rail mount.

$36.83 – $95.30Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ4104-7HG41 — Identification
ParameterValue
Product designationMiniature circuit breakers
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SJ4104-7HG41 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage category3
5SJ4104-7HG41 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodon standard mounting rail
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height110 mm
Depth70 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SJ4104-7HG41 — Environmental
ParameterValue
IP protection classIP20, with connected conductors, IP 40 in the handle range
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SJ4104-7HG41 SENTRON MCB — C-curve, 1-pole, 10/15 kA

Its C-curve tripping characteristic (magnetic trip at 5–10× In) makes it suited for moderate inrush loads like motor starters and contactor coils, where the short-duration surge stays below the magnetic threshold but a hard fault clears within the 10 kA interrupting rating per EN 60898, or 15 kA per IEC 60947-2 at 400 V AC. The 18 mm width (1 modular unit) snaps onto standard DIN rail per EN 60715, and the combined top/bottom terminals accept Cu conductors at 3.5 Nm torque. Rated for AC 400 V and DC 60 V, with an insulation voltage (Ui) of 440 V AC.

Sourcing & lifecycle — active, quoted to order

For compliance documentation, the 5SJ4 series is designed to EN 60898 and IEC 60947-2, and halogen-free and silicon-free construction supports clean-room and sensitive-electronics environments.

Fit and mounting — 1 MW, DIN-rail, any position

Height is 110 mm. Mounting position is unrestricted — vertical, horizontal, or inverted — which simplifies layout in tight gland-plate zones. Vibration resistance to 50 m/s² at 25–150 Hz and 60 m/s² at 35 Hz (4 s) covers most machine-mounted applications without supplementary bracing.

Frequently asked questions

What are the key ratings for this MCB?

1-pole, C-curve (magnetic trip 5–10× In), 10 kA interrupting rating per EN 60898 and 15 kA per IEC 60947-2 at 400 V AC. Rated for AC 400 V and DC 60 V. Insulation voltage (Ui) 440 V AC. Pollution degree 3, overvoltage category 3.

How do I source the 5SJ4104-7HG41?

This part is sourced to order against an RFQ. Submit a request for current pricing and lead time — no shelf stock quantity is published here.

Will the 5SJ4104-7HG41 drop into a panel specified for the 5SL4363-7?

Both are 1-pole C-curve MCBs from the Siemens SENTRON family, but the 5SL4363-7 is a different series with a different interrupting rating and terminal design. The 5SJ4104-7HG41 uses combined terminals (top and bottom) and is rated 10 kA per EN 60898 / 15 kA per IEC 60947-2. Verify the required SCCR and terminal compatibility before substitution — the footprint (18 mm wide, DIN-rail) is the same, but coordination and selectivity may differ.

MPN
5SJ4104-7HG41