Skip to main content
Siemens 5SJ4105-7HG41 — 1-Pole MCB (DIN Rail)

Siemens 5SJ4105-7HG41 SENTRON MCB, 1-pole C-curve 0.5 A

MPN5SJ4105-7HG41
Active

Siemens SENTRON 5SJ4 series, miniature circuit breaker, 1-pole, C-curve, 0.5 A rated current, DIN rail mount, IP20, 70 mm depth, 18 mm width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ4105-7HG41 — Identification
ParameterValue
Product designationMiniature circuit breakers
Brand nameSENTRON
Number of poles1
Application suitabilityMechanical engineering / industry
5SJ4105-7HG41 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage category3
5SJ4105-7HG41 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodon standard mounting rail
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height110 mm
Depth70 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SJ4105-7HG41 — Environmental
ParameterValue
IP protection classIP20, with connected conductors, IP 40 in the handle range
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SJ4105-7HG41 — SENTRON 1-pole C-curve MCB, 0.5 A

The Siemens 5SJ4105-7HG41 is a 1-pole miniature circuit breaker from the SENTRON 5SJ4 series, rated 0.5 A at 30 °C with a C-curve tripping characteristic — the standard choice for general-purpose branch-circuit protection in industrial control panels where moderate inrush (transformers, contactor coils, small motor starters) is expected. Rated for 60 V DC maximum, it also covers DC control circuits common in 24 V and 48 V automation loops, though the C-curve is primarily selected for AC applications.

At elevated panel temperatures the breaker derates linearly: 0.48 A at 45 °C, 0.46 A at 50 °C, 0.44 A at 55 °C, and 0.42 A at 60 °C. C-curve trips at 5–10× rated current, so a 0.5 A breaker clears between 2.5 A and 5 A magnetic trip — appropriate for protecting a 0.5 A control transformer or a small solenoid bank where the inrush is a few times the load current.

The part is sealable, halogen-free, and silicon-free — relevant for panels that require clean-room or food-grade material restrictions.

Frequently asked questions

Will 5SJ4105-7HG41 drop into a panel specified around 5SY4140-7 without rewiring?

Both are 1-pole C-curve MCBs on standard DIN rail with the same 18 mm width, so mechanical fit is identical. However, 5SY4140-7 is rated 40 A versus 0.5 A — the conductor sizing and upstream protection must match the 0.5 A rating. If the panel wiring is sized for 40 A, you cannot simply swap in a 0.5 A breaker without rewiring the branch circuit.

MPN
5SJ4105-7HG41