Skip to main content
Siemens 5SJ4105-8HG40 — 1-Pole MCB (DIN Rail)

Siemens 5SJ4105-8HG40 SENTRON MCB, 1P D 0.5A 10kA

MPN5SJ4105-8HG40
Active

Siemens SENTRON 5SJ4 series, 1-pole miniature circuit breaker, D tripping characteristic, 0.5 A rated current, 10 kA breaking capacity per EN 60898, 18 mm width, 70 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ4105-8HG40 — Identification
ParameterValue
Product designationMiniature circuit breakers
Brand nameSENTRON
Number of poles1
Application suitabilityMechanical engineering / industry
5SJ4105-8HG40 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Rated value (EN 60898)10 kA
Overvoltage category3
5SJ4105-8HG40 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodon standard mounting rail
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth70 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SJ4105-8HG40 — Environmental
ParameterValue
IP protection classIP20, with connected conductors, IP 40 in the handle range
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

What this MCB does and where it fits

The Siemens SENTRON 5SJ4105-8HG40 is a 1-pole miniature circuit breaker with a D tripping characteristic, rated 0.5 A at AC and 10 kA breaking capacity per EN 60898. The 70 mm installation depth matches the common SENTRON 5SJ4 footprint, so it retrofits into existing distribution boards without re-spacing the busbar.

The 0.5 A rating holds at 30 °C and 40 °C ambient, but above that you need to derate: 0.48 A at 45 °C, 0.46 A at 50 °C, 0.44 A at 55 °C, and 0.42 A at 60 °C. The terminal torque spec is 3.5 Nm for Cu conductors rated 60/75 °C, which is a standard value for this class.

Environmental and compliance fit

Halogen-free and silicon-free construction, which matters for panels in clean-room or semiconductor-adjacent environments where outgassing can contaminate optics or contacts. The IP20 rating on the body (IP40 in the handle area) is typical for enclosed distribution boards — no washdown rating, so keep it behind a panel door in wet areas.

Frequently asked questions

Where can I buy the 5SJ4105-8HG40 and get a price?

This part is sourced through independent distribution channels. Submit an RFQ — availability and current pricing are confirmed at quote time. No stock figures or price lists are published here.

What is the breaking capacity of this MCB?

10 kA rated breaking capacity per EN 60898, which covers most residential and light commercial distribution boards. For higher fault-current installations (above 10 kA), you would need a current-limiting upstream device or a higher-rated breaker.

What compliance documentation does Siemens provide for the 5SJ4105-8HG40?

The part carries IEC and EN certifications implicit in the 10 kA rating per EN 60898. It is halogen-free and silicon-free. Full declarations (CE, UKCA, RoHS, REACH) are available from Siemens documentation portals; the product designation follows IEC 81346-2 and DIN EN 61346-2 for panel labeling.

MPN