Skip to main content
Siemens 5SJ4108-7HG40 — 1-Pole MCB (DIN Rail)

Siemens 5SJ4108-7HG40 SENTRON MCB, 1P C-curve, 10 kA

MPN5SJ4108-7HG40
Active

Siemens SENTRON 5SJ4 series, 5SJ4108-7HG40, 1-pole miniature circuit breaker, C characteristic, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 400 V AC, 60 V DC, 18 mm wide, DIN rail mount.

$27.94 – $83.20Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ4108-7HG40 — Identification
ParameterValue
Product designationMiniature circuit breakers
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SJ4108-7HG40 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage category3
5SJ4108-7HG40 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodon standard mounting rail
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth70 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SJ4108-7HG40 — Environmental
ParameterValue
IP protection classIP20, with connected conductors, IP 40 in the handle range
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

It carries a C tripping characteristic, which means it handles moderate inrush currents typical of motor starters and small transformers without nuisance tripping — a solid fit for general-purpose loads in mechanical engineering and industrial environments. Rated breaking capacity is 10 kA per EN 60898 at 400 V AC, and 15 kA per IEC 60947-2 — the higher figure applies when the breaker is installed per the standard's industrial rules, giving you a safety margin for high-fault locations near the main distribution. AC rated voltage is 400 V, DC rated voltage is 60 V, and insulation voltage (Ui) is 440 V AC.

The 5SJ4108-7HG40 is halogen-free and silicon-free, which simplifies compliance documentation for RoHS and REACH declarations — a plus for quality and documentation teams tracking material restrictions.

Installation Notes

Vibration resistance is 50 m/s² at 25 to 150 Hz and 60 m/s² at 35 Hz (4-second duration) — adequate for most industrial machinery but not for extreme high-vibration applications like crushers or large reciprocating compressors without additional support. The sealable design allows padlocking in the OFF position for lockout/tagout procedures.

Frequently asked questions

What is the breaking capacity of the 5SJ4108-7HG40?

Rated breaking capacity is 10 kA according to EN 60898 at 400 V AC, and 15 kA according to IEC 60947-2. The higher IEC figure applies when the breaker is used under the industrial installation rules of that standard.

What compliance documentation is available for the 5SJ4108-7HG40?

The breaker is halogen-free and silicon-free, supporting RoHS and REACH compliance. The SENTRON series carries CE marking and is designed to EN 60898 and IEC 60947-2 standards.

MPN