Skip to main content
Siemens 5SJ4113-8HG41 — 1-Pole MCB (DIN Rail)

Siemens 5SJ4113-8HG41 SENTRON MCB, 1P D-curve, 10 kA

MPN5SJ4113-8HG41
Active

Siemens SENTRON 5SJ4 miniature circuit breaker, 1-pole, D-curve, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 400 V AC, 60 V DC, 70 mm depth, 18 mm width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ4113-8HG41 — Identification
ParameterValue
Product designationMiniature circuit breakers
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SJ4113-8HG41 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Overvoltage category3
5SJ4113-8HG41 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodon standard mounting rail
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height110 mm
Depth70 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SJ4113-8HG41 — Environmental
ParameterValue
IP protection classIP20, with connected conductors, IP 40 in the handle range
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

What it is and what it does

The Siemens 5SJ4113-8HG41 is a 1-pole SENTRON miniature circuit breaker from the 5SJ4 series, carrying a D tripping characteristic. That D curve means it's built for loads with high inrush — think motor starters, transformers, or welding equipment — where the magnetic trip threshold is higher than a B or C curve, so nuisance tripping on startup is less likely. Rated 10 kA breaking capacity per EN 60898 and 15 kA per IEC 60947-2 at 400 V AC, with a DC rating of 60 V. The 15 kA figure under IEC 60947-2 is the one that matters for industrial panel coordination — it tells you this breaker can interrupt a fault up to that level without welding its contacts or cascading upstream. Snaps onto standard DIN rail (35 mm), takes any mounting position, and its 70 mm depth plus 18 mm width (1 MW) fits a standard modular enclosure. Pollution degree 3 and overvoltage category 3 mean it's rated for the typical industrial control panel environment — not just clean, dry switchgear rooms.

Installation notes

Sealable (padlockable handle) and halogen-free / silicon-free construction — relevant if the panel sits in a clean room or a food-processing area where outgassing or silicone contamination is a concern. Ambient temperature range -40 °C to 75 °C, with 95% humidity tolerance. That covers most indoor industrial environments, including unheated warehouses or outdoor-rated enclosures.

MPN
5SJ4113-8HG41