Skip to main content
Siemens 5SJ4125-8HG42 — 1-Pole MCB (DIN Rail)

Siemens 5SJ4125-8HG42 SENTRON MCB, 1P D-curve, 10 kA

MPN5SJ4125-8HG42
Active

Siemens SENTRON 5SJ4125-8HG42 miniature circuit breaker, 1-pole, D tripping characteristic, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 400 V AC / 60 V DC.

$98.98Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ4125-8HG42 — Identification
ParameterValue
Product designationMiniature circuit breakers
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SJ4125-8HG42 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Overvoltage category3
5SJ4125-8HG42 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodon standard mounting rail
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height121 mm
Depth70 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SJ4125-8HG42 — Environmental
ParameterValue
IP protection classIP20, with connected conductors, IP 40 in the handle range
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SJ4125-8HG42 is a 1-pole miniature circuit breaker with a D tripping characteristic, rated 10 kA breaking capacity per EN 60898 and 15 kA per IEC 60947-2. That D-curve means it's built for loads with high inrush — think motor starters, transformers, or welding equipment — where the magnetic trip holds off until about 10–20 times rated current, so nuisance trips don't pull a line down on startup. The 15 kA rating under IEC 60947-2 gives you industrial-grade fault clearing; the 10 kA under EN 60898 covers the residential/commercial side. It's rated 400 V AC and 60 V DC, so it handles standard panel voltages and some DC control circuits.

Sealable — you can lock the handle position with a padlock for lockout/tagout. Vibration resistance is 50 m/s² at 25–150 Hz and 60 m/s² at 35 Hz (4 seconds). Suitable for mechanical engineering and industrial environments per the manufacturer's suitability note.

Frequently asked questions

What is the breaking capacity of this breaker?

10 kA per EN 60898 and 15 kA per IEC 60947-2. The higher IEC rating applies in industrial installations where the prospective fault current is greater.

What is the tripping characteristic and what loads is it for?

D-curve — magnetic trip threshold is roughly 10–20 times rated current. It's intended for loads with high inrush, such as motors, transformers, or welding equipment, to avoid nuisance tripping on startup.

What are the mounting dimensions?

18 mm wide (1 modular unit), 70 mm deep, 121 mm high. Snaps onto standard 35 mm DIN rail; any mounting position is allowed.

MPN