Siemens 5SJ4145-8HG41 — 1-Pole MCB (DIN Rail)

Siemens 5SJ4145-8HG41 SENTRON MCB, 1P, D-45A, 10kA

MPN5SJ4145-8HG41
Active

Siemens SENTRON 5SJ4 miniature circuit breaker, 1-pole, D tripping characteristic, 45 A rated current, 10 kA breaking capacity per EN 60898, 400 V AC, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ4145-8HG41 — Identification
ParameterValue
Product designationMiniature circuit breakers
Brand nameSENTRON
Number of poles1
Application suitabilityMechanical engineering / industry
5SJ4145-8HG41 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Rated value (EN 60898)10 kA
Overvoltage category3
5SJ4145-8HG41 — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height110 mm
Depth70 mm
Installation depth70 mm
SealableYes
5SJ4145-8HG41 — Environmental
ParameterValue
IP protection classIP20, with connected conductors, IP 40 in the handle range
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SJ4145-8HG41 is a 1-pole miniature circuit breaker with a D tripping characteristic, rated 45 A at 400 V AC. The 10 kA breaking capacity per EN 60898 covers most commercial and light industrial panel fault levels; the 15 kA rating per IEC 60947-2 gives additional headroom for industrial distribution boards where the prospective short-circuit current is higher. Mounts on standard DIN rail, occupies one width unit (18 mm).

Rated for ambient temperatures from -25 to +55 °C, storage from -40 to +75 °C. Protection class IP20 with connected conductors; Vibration resistance tested at 50 m/s² over 25–150 Hz and 60 m/s² at 35 Hz for 4 seconds, covering typical machine-mounted panel vibration. Sealable for lockout/tagout applications. Overvoltage category III, suitable for fixed-installation distribution boards. The product carries designations per DIN EN 61346-2 and DIN EN 81346-2 (function code F).

Frequently asked questions

Where can I buy 5SJ4145-8HG41?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 5SJ4145-8HG41?

10 kA rated breaking capacity per EN 60898, and 15 kA per IEC 60947-2 at 400 V AC.

What is the difference between 5SJ4145-8HG41 and 5SY7140-8CC?

The 5SY7140-8CC is a 1-pole C-curve 40 A MCB in the same SENTRON 5SY series. The D-curve on the 5SJ4145-8HG41 (10–20× In magnetic trip) suits motor and transformer loads, while the C-curve (5–10× In) suits general distribution. Both mount on standard DIN rail in the same 18 mm footprint, so a panel swap between them is mechanically straightforward, but the 5SJ4145-8HG41 carries a higher 45 A rating versus 40 A.