Skip to main content
Siemens 5SJ4160-6HG40 — 1-Pole MCB (DIN Rail)

Siemens 5SJ4160-6HG40 1-Pole MCB, B-Curve 60A, 15kA IEC, DIN Rail

MPN5SJ4160-6HG40
Active

Siemens, SENTRON 5SJ4 series, 1-pole MCB (DIN Rail), order code 5SJ4160-6HG40, B-tripping characteristic, 60 A, 400 V AC, 60 V DC, 15 kA per IEC 60947-2, 70 mm depth, IP20/IP40, sealable, halogen-free.

$112.06Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ4160-6HG40 — Identification
ParameterValue
Product designationMiniature circuit breakers
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SJ4160-6HG40 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Overvoltage category3
5SJ4160-6HG40 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodon standard mounting rail
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth70 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SJ4160-6HG40 — Environmental
ParameterValue
IP protection classIP20, with connected conductors, IP 40 in the handle range
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

It occupies one 18 mm modular width on DIN rail and has a depth of 70 mm – a standard envelope for control cabinet and distribution board layouts. Rated breaking capacity: 15 kA and 10 kA.

Environmental and mechanical resilience

The breaker is sealable, which allows locking the cover to prevent unauthorized access in safety-critical circuits – a common requirement in industrial machine disconnect panels. It is halogen-free and silicon-free, suitable for environments where outgassing or contamination can affect nearby electronics (e.g., clean rooms or medical equipment). The design accepts copper conductors with a tightening torque of 3.5 Nm (31 lb·in) – compatible with typical 60/75 °C rated wire. Combined (screw + clamp) terminals on both top and bottom simplify wiring and reduce the number of terminal types on the panel.

Frequently asked questions

Does 5SJ4160-6HG40 fit as a direct replacement for existing Siemens MCB with same form factor and B-curve?

Yes. The 5SJ4160-6HG40 is a 1-pole, 18 mm wide, B-curve breaker. It mounts on standard DIN rail, so it replaces any similarly rated Siemens MCB (e.g., 5SX or 5SN series) with the same trip characteristics and amperage, provided the voltage and breaking capacity requirements match.

Does 5SJ4160-6HG40 comply with IEC 60947-2 for industrial applications at 15 kA breaking capacity?

Yes. The breaker is rated 15 kA per IEC 60947-2, making it suitable for industrial networks with higher fault currents. It also carries a 10 kA rating per EN 60898 for residential/commercial applications.

What is the maximum DC voltage rating of 5SJ4160-6HG40 for use in photovoltaic combiner boxes?

The maximum DC voltage rating is 60 V. This limits its use to low-voltage PV arrays (e.g., small off-grid systems) where the string voltage does not exceed 60 V. For higher DC voltages, a different MCB with a higher DC rating is needed.

Is 5SJ4160-6HG40 sealable to prevent unauthorized access in safety-critical circuits?

Yes. The breaker is explicitly marked as sealable, allowing a locking mechanism to be applied to prevent tampering or unauthorized resetting – a requirement in many industrial safety circuits.

Are the halogen-free and silicon-free properties of 5SJ4160-6HG40 verified by third-party certification?

The specifications list halogen-free and silicon-free as part of the product design. These claims are based on the manufacturer's material declaration; verify with Siemens if internal compliance documentation or third-party certification is required for your specific application.

What are the exact width and depth for DIN rail mounting to ensure proper spacing in a panel?

Width is 18 mm (1 modular unit) and depth is 70 mm. Height is 90 mm. These dimensions match standard DIN-rail MCB footprints, allowing straightforward spacing calculations in your panel layout.

MPN