Skip to main content
Siemens 5SJ4202-8HG41 — 2-Pole MCB (DIN Rail)

Siemens 5SJ4202-8HG41 SENTRON MCB, 2-Pole D-Curve, 10 kA

MPN5SJ4202-8HG41
Active

Siemens SENTRON 5SJ4 series, 2-pole miniature circuit breaker, D tripping characteristic, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 400 V AC / 60 V DC, 36 mm wide, 70 mm deep.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SJ4202-8HG41 — Identification
ParameterValue
Product designationMiniature circuit breakers
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SJ4202-8HG41 — Electrical
ParameterValue
Number of poles2
5SJ4202-8HG41 — Protection
ParameterValue
Tripping characteristic classD
Overvoltage category3
5SJ4202-8HG41 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height110 mm
Depth70 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors, IP 40 in the handle range
5SJ4202-8HG41 — Environmental
ParameterValue
Pollution degree3
5SJ4202-8HG41 — Specifications
ParameterValue
At AC rated value400 V
According to EN 60898 rated value10 kA

Product details

It is rated 10 kA breaking capacity per EN 60898 and 15 kA per IEC 60947-2 at 400 V AC, with a DC rating of 60 V. The 70 mm depth is a standard panel depth; no special enclosure clearance needed.

Ratings and their meaning for the buyer

The 15 kA rating under IEC 60947-2 gives headroom for industrial distribution boards with higher fault levels — the higher standard certifies the breaker for use as a branch-circuit protective device in motor starter combinations. The D-curve trips magnetically between 10× and 20× In, so it holds through motor starting current without nuisance trips. Overvoltage category 3 and pollution degree 3 mean it is rated for fixed-installation distribution panels, not plug-in portable equipment.

Frequently asked questions

How do I get current pricing and availability for 5SJ4202-8HG41?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels.

Will 5SJ4202-8HG41 drop into a panel specified around 5SY4140-7 without rewiring?

Both are 2-pole DIN-rail MCBs in the same SENTRON family, but verify the tripping characteristic and breaking capacity against your design. The 5SJ4202-8HG41 is a D-curve rated 10 kA (EN 60898) / 15 kA (IEC 60947-2); the 5SY4140-7 is a different curve and rating. The physical footprint (36 mm wide, 70 mm deep) and DIN-rail mounting are the same, so it will mechanically fit without panel modification, but the electrical protection coordination must be reviewed.

What compliance documentation does this brand provide for 5SJ4202-8HG41?

As a Siemens SENTRON product, it carries CE marking and is designed to EN 60898 and IEC 60947-2. RoHS and REACH compliance documentation is standard for the series. The part is halogen-free and silicon-free.

MPN
5SJ4202-8HG41