Skip to main content
Siemens 5SJ4210-8HG41 — 2-Pole MCB (DIN Rail)

Siemens 5SJ4210-8HG41 SENTRON MCB, 2-Pole D-Curve, 10 kA

MPN5SJ4210-8HG41
Active

Siemens SENTRON 5SJ4210-8HG41, 2-pole miniature circuit breaker, D tripping characteristic, 10 kA breaking capacity per EN 60898, 15 kA per IEC 60947-2, rated 400 V AC / 60 V DC, 36 mm wide, DIN rail mount.

$82.55Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ4210-8HG41 — Identification
ParameterValue
Product designationMiniature circuit breakers
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SJ4210-8HG41 — Electrical
ParameterValue
Number of poles2
5SJ4210-8HG41 — Protection
ParameterValue
Tripping characteristic classD
Overvoltage category3
5SJ4210-8HG41 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height110 mm
Depth70 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors, IP 40 in the handle range
5SJ4210-8HG41 — Environmental
ParameterValue
Pollution degree3
5SJ4210-8HG41 — Specifications
ParameterValue
At AC rated value400 V
According to EN 60898 rated value10 kA

Product details

What this MCB is and where it fits

The Siemens 5SJ4210-8HG41 is a 2-pole SENTRON miniature circuit breaker with a D tripping characteristic, designed to protect branch circuits against overloads and short circuits in industrial control panels. It snaps onto a standard DIN rail and occupies 2 modular width units (36 mm). The D curve means it tolerates high inrush currents — the magnetic trip threshold is 10 to 20 times rated current — making it the right choice for motor starter circuits, transformers, or other loads with a heavy starting surge.

Breaking capacity and voltage ratings

Rated breaking capacity is 10 kA per EN 60898 and 15 kA per IEC 60947-2. The higher IEC figure is the one that matters for industrial panel coordination — it tells you this breaker can safely clear a fault up to 15 kA at the rated voltage without welding its contacts or failing catastrophically. AC rated voltage is 400 V; DC rated voltage is 60 V. Insulation voltage (Ui) is rated at 440 V AC.

Frequently asked questions

What is the breaking capacity of 5SJ4210-8HG41?

10 kA per EN 60898 and 15 kA per IEC 60947-2. The IEC 60947-2 rating is the one used for industrial panel coordination.

What does the D tripping curve mean on this MCB?

The D characteristic has a magnetic trip threshold of 10 to 20 times rated current, so it handles high inrush loads like motors and transformers without nuisance tripping.

Will 5SJ4210-8HG41 fit on a standard DIN rail?

Yes, it snaps onto a standard mounting rail and occupies 2 modular width units (36 mm wide).

Where can I buy 5SJ4210-8HG41?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SJ4210-8HG41