Skip to main content
Siemens 5SJ4218-7HG41 — 2-Pole MCB (DIN Rail)

Siemens 5SJ4218-7HG41 SENTRON MCB, 2P C-Curve, 10kA/15kA

MPN5SJ4218-7HG41
Active

Siemens SENTRON 5SJ4 series, 5SJ4218-7HG41 miniature circuit breaker, 2-pole, C-curve trip characteristic, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 400 V AC, 60 V DC, 2 MW, IP20/IP40, on standard mounting rail.

$76.20Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ4218-7HG41 — Identification
ParameterValue
Product designationMiniature circuit breakers
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SJ4218-7HG41 — Electrical
ParameterValue
Number of poles2
5SJ4218-7HG41 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage category3
5SJ4218-7HG41 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height110 mm
Depth70 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors, IP 40 in the handle range
5SJ4218-7HG41 — Environmental
ParameterValue
Pollution degree3
5SJ4218-7HG41 — Specifications
ParameterValue
At AC rated value400 V
According to EN 60898 rated value10 kA

Product details

The Siemens 5SJ4218-7HG41 is a 2-pole SENTRON miniature circuit breaker with a C-curve trip characteristic, meaning it trips at 5 to 10 times rated current — the standard choice for motor circuits, transformers, and general inductive loads where a moderate inrush is expected without nuisance tripping. Breaking capacity is dual-rated: 10 kA per EN 60898 for residential/commercial branch circuits, and 15 kA per IEC 60947-2 for industrial panel coordination — the higher figure is what matters when you're sizing for fault-current withstand in a factory distribution board. Rated for 400 V AC and 60 V DC, this 2-module-wide (36 mm) unit snaps onto standard DIN rail in any mounting position, with a 70 mm installation depth that fits most enclosure depths without crowding the gland plate.

Mounts on standard 35 mm DIN rail per EN 60715; the 36 mm width occupies exactly two modular units, leaving predictable space for adjacent breakers or accessories in a multi-pole assembly. Ambient temperature range spans -40 °C to +75 °C, with vibration resistance to 50 m/s² at 25–150 Hz and 60 m/s² at 35 Hz — suitable for machinery-mounted panels subject to continuous vibration.

Termination and wiring notes

MPN
5SJ4218-7HG41