Skip to main content
Siemens 5SJ4314-8HG41 — Miniature Circuit Breakers (MCB)

Siemens SENTRON 5SJ4314-8HG41 MCB, D Curve, 0.3 A, 3-Pole

MPN5SJ4314-8HG41
Active

Siemens SENTRON 5SJ4314-8HG41, miniature circuit breaker, 3-pole, D tripping characteristic, 0.3 A rated current at 30 °C, DIN rail mount, IP20/IP40.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SJ4314-8HG41 — Ratings
ParameterValue
Overvoltage category3
5SJ4314-8HG41 — Mechanical
ParameterValue
Width54 mm
Height110 mm
Depth70 mm

Product details

The Siemens SENTRON 5SJ4314-8HG41 is a 3-pole miniature circuit breaker with a D tripping characteristic, rated at 0.3 A at 30 °C. It's part of the 5SJ4 series, designed for DIN-rail mounting in control panels and distribution boards. At 0.3 A, it's sized for small control transformers or signal circuits, not main power feeds.

The D characteristic provides a magnetic trip threshold of 10 to 20 times the rated current, so this 0.3 A breaker will hold through short-duration surges up to roughly 3 to 6 A before the magnetic coil reacts. That's the right choice for a small control transformer or a relay coil bank where the inrush is brief but high. The thermal element handles the continuous overload side — at 40 °C it still carries the full 0.3 A, but at 60 °C it derates to 0.25 A. Rated for AC/DC operation with a maximum DC voltage of 60 V. That covers most 24 VDC control circuits and 48 VDC telecom supplies, but not a 125 VDC battery bank. The housing carries IP20 with connected conductors, and IP40 in the handle range. That's standard for a DIN-rail MCB inside a closed panel — no special washdown rating. If the breaker is mounted where operators can touch the handle, the IP40 on the toggle is enough for accidental splashes, but not hose-down.

Sealable — you can wire a seal through the housing to prevent tampering, which matters for revenue-grade metering or safety-critical circuits where the breaker setting must stay locked. Halogen-free and silicon-free construction reduces toxic smoke and corrosive byproducts in a fault scenario, a consideration for enclosed switchgear or clean-room adjacent panels.

Frequently asked questions

What is the 5SJ4314-8HG41 used for?

It's a 3-pole miniature circuit breaker with a D tripping characteristic, rated 0.3 A. The D curve suits loads with high inrush current — small motors, control transformers, solenoid banks — where a standard C curve would nuisance-trip on startup.

What is the depth of the 5SJ4314-8HG41?

The depth is 70 mm, which is also the installation depth. It sits flush with other 5SJ4 series breakers on the same DIN rail.

What is the width of the 5SJ4314-8HG41?

The width is 54 mm, which corresponds to 3 modular width units at 18 mm per pole — the standard Siemens footprint.

Where can I buy the 5SJ4314-8HG41 and get current pricing?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance documentation does Siemens provide for the 5SJ4314-8HG41?

The product carries the SENTRON brand and is designed to IEC standards. The housing is halogen-free and silicon-free. For specific RoHS, REACH, or UL documentation, request the manufacturer's declaration with your RFQ.

MPN
5SJ4314-8HG41