Skip to main content
Siemens 5SJ4360-8HG41 — Miniature Circuit Breakers (MCB)

Siemens 5SJ4360-8HG41 60A 3-Pole MCB, D Curve, 10kA EN

MPN5SJ4360-8HG41
Active

Siemens SENTRON 5SJ4 series, 3-pole miniature circuit breaker, 60 A, D characteristic, 10 kA breaking capacity per EN 60898, 15 kA per IEC 60947-2, 3-module width.

$700.86Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SJ4360-8HG41 — Ratings
ParameterValue
Overvoltage category3
5SJ4360-8HG41 — Mechanical
ParameterValue
Width54 mm
Height110 mm
Depth70 mm

Product details

D-curve trip for motor and transformer starts

That D-curve means it tolerates the inrush of motor and transformer loads — typically 10 to 14 times rated current for a short duration — without nuisance tripping on startup. Rated 400 V AC and 60 V DC, it covers standard 3-phase panel feeds and some DC branch circuits.

Breaking capacity: EN 60898 vs IEC 60947-2

For DC branch protection, the rated voltage is 60 V — confirm the system voltage stays within that limit.

Active production, sourced per RFQ

If you are replacing an existing breaker in a panel, verify the 54 mm width (3-module) fits the existing DIN-rail space and that the D-curve matches the load type.

IP20 with connected conductors, IP40 in the handle area — suitable for enclosed industrial panels where the breaker is not exposed to washdown. Vibration resistance is 50 m/s² at 25 to 150 Hz, and 60 m/s² at 35 Hz for 4 seconds — adequate for machine-mounted panels on pumps or conveyors. Sealable for lockout/tagout compliance.

Frequently asked questions

Where can I buy 5SJ4360-8HG41 and get a price?

The 5SJ4360-8HG41 is sourced to order against an RFQ through independent distribution. Submit your BOM quantity for a current price and lead-time confirmation — no stock-holding claim is made here.

Is 5SJ4360-8HG41 suitable for DC applications?

Yes, it is rated for DC circuits up to 60 V. For DC branch protection, confirm the system voltage does not exceed 60 V and that the D-curve's magnetic trip threshold is appropriate for the DC load profile.

What is the breaking capacity of 5SJ4360-8HG41?

10 kA per EN 60898 for standard commercial installations, and 15 kA per IEC 60947-2 for industrial panel applications. The higher 15 kA figure applies when the prospective fault current exceeds 10 kA.

MPN
5SJ4360-8HG41