Skip to main content
Siemens 5SJ6102-7 — 1-Pole MCB (DIN Rail)

Siemens SENTRON 5SJ6102-7 MCB, 1-Pole C 2A 6kA

MPN5SJ6102-7

Siemens SENTRON 5SJ6 series, miniature circuit breaker, 1-pole, C-curve, 2 A, 6 kA per EN 60898, 240 V AC, 70 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SJ6102-7 — Identification
ParameterValue
Product designationMiniature circuit breakers
Brand nameSENTRON
Number of poles1
5SJ6102-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage category3
5SJ6102-7 — Mounting & Connection
ParameterValue
Mounting positionany
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SJ6102-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SJ6102-7 — SENTRON 1-pole C-curve 2 A MCB

The Siemens SENTRON 5SJ6102-7 is a 1-pole miniature circuit breaker with a C tripping characteristic, rated 2 A at 240 V AC and a 6 kA breaking capacity per EN 60898 (also rated 6 kA per IEC 60947-2).

At 2 A, it's a control-circuit protector, not a feeder breaker. The 6 kA breaking capacity at 240 V AC is the standard domestic/light-commercial fault level per EN 60898; the same 6 kA rating per IEC 60947-2 confirms it also meets the industrial standard for the same fault level. The 1-pole form factor and single width unit mean it fits a standard 18 mm DIN slot — no panel rework needed to swap in a like-for-like replacement. For DC circuits, the maximum rated voltage is 60 V — useful for control-voltage DC auxiliaries within that limit. The breaker is rated for any mounting position and any power-supply cord position, giving flexibility in tight enclosures. Environmental range covers -40 °C to +75 °C storage and operation, with periodic humidity up to +55 °C at 95% RH. Vibration resistance per IEC 60068-2-6 is 50 m/s² at 25 to 150 Hz and 60 m/s² at 10 to 150 Hz — sufficient for installation near moderate industrial machinery. Mechanical service life is 20 000 switching cycles typical.

Compliance and approvals

Degree of pollution 2 and overvoltage category III are standard for fixed-installation distribution boards. Touch protection is provided on the terminals.

The 5SJ6102-7 carries a current-production lifecycle status, so it remains in the SENTRON catalog as an active order code. For a BOM line that specifies this exact 5SJ6-series 2 A C-curve MCB, the part is the right-sized spec — no need to second-source unless the panel was originally built around a different footprint.

Frequently asked questions

How do I get current pricing and availability for 5SJ6102-7?

Submit an RFQ through this listing. The part is sourced to order via independent distribution, and a confirmed price and lead time are provided at quote time.

Will 5SJ6102-7 drop into a panel that was specified around 5SL6563-7BB without rewiring?

No — the 5SL6563-7BB is a 2-pole (1P+N) 63 A MCB with a 76 mm depth and 36 mm width, while the 5SJ6102-7 is a 1-pole 2 A unit with 70 mm depth and 18 mm width. The footprint, current rating, and pole count are different; a direct swap is not possible without panel rework.

What is 5SJ6102-7's listed maximum and minimum temperature?

The storage and operating temperature range is -40 °C minimum to +75 °C maximum.

What compliance documentation does this brand provide for 5SJ6102-7?

The part is halogen-free and silicon-free, rated per EN 60898 and IEC 60947-2, with overvoltage category III and pollution degree 2. Standard Siemens SENTRON documentation (declaration of conformity, CE marking) applies; specific RoHS/REACH declarations are available from Siemens upon request.

MPN
5SJ6102-7