Siemens 5SJ6116-7FC — 1-Pole MCB (DIN Rail)

Siemens 5SJ6116-7FC SENTRON MCB, 1P C 16A 6kA

MPN5SJ6116-7FC

Siemens SENTRON 5SJ6116-7FC, miniature circuit breaker, 1-pole, C-curve, 16 A, 6 kA per EN 60898, 1 MW width, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ6116-7FC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityResidential buildings/infrastructure
5SJ6116-7FC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Overvoltage categoryIII
5SJ6116-7FC — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SJ6116-7FC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The 5SJ6116-7FC is a Siemens SENTRON miniature circuit breaker — 1-pole, 16 A rated current, C-curve trip characteristic, and a 6 kA breaking capacity certified to EN 60898. Single-pole design (1P) switches the line conductor only; neutral is not switched. Rated for 250 V AC single-phase or 400 V AC multi-phase operation. The 18 mm width (1 modular unit) snaps onto standard DIN rail — fits any 1-MW slot in a consumer unit or distribution board.

Temperature derating and service life

Rated 16 A at 30 °C ambient; at 40 °C the continuous current drops to 15.23 A, and at 45 °C to 14.88 A — a standard thermal derating curve that matters when the breaker shares a crowded enclosure with other heat sources.

Mounting and environment

Mounts in any position — vertical, horizontal, or inverted — on standard DIN rail. IP20 protection with connected conductors; suitable for dry indoor enclosures.

Frequently asked questions

What is the breaking capacity of 5SJ6116-7FC?

6 kA per EN 60898 at 400 V AC.

Will 5SJ6116-7FC drop into a panel specified around 5SY6013-7 without rewiring?

Yes — both are 1-MW (18 mm wide) SENTRON MCBs with the same 76 mm depth and 90 mm height, same DIN-rail mounting, same IP20 rating. The 5SJ6116-7FC is a 16 A C-curve; the 5SY6013-7 is a 13 A C-curve. Footprint and terminal layout are identical, so no rewiring needed for a swap at the same current rating.

Where can I buy 5SJ6116-7FC?