Siemens 5SJ6116-7RC SENTRON MCB, 1P, 16A, C Curve, 6kA

MPN5SJ6116-7RC

Siemens SENTRON 5SJ6116-7RC, 1-pole miniature circuit breaker, 16 A rated current, C tripping characteristic, 6 kA breaking capacity per EN 60898, 240 V AC, 1 MW width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ6116-7RC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityretail line
5SJ6116-7RC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation classNo
Overvoltage categoryIII
5SJ6116-7RC — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SJ6116-7RC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SJ6116-7RC is a SENTRON retail-line miniature circuit breaker — a 1-pole, 16 A, C-curve unit rated for 6 kA breaking capacity per EN 60898 at 240 V AC. The single-module width (18 mm) means it snaps into any standard DIN-rail panel, and the 76 mm depth fits flush in shallow enclosures.

The 6 kA breaking capacity per EN 60898 is the key coordination number — it tells you this breaker can safely interrupt a fault current up to 6,000 A at 240 V AC without welding its contacts or failing catastrophically. That's adequate for most retail and commercial sub-distribution boards fed from a transformer of typical impedance, but it won't hold up on a high-capacity industrial bus where the prospective short-circuit current exceeds 6 kA. Rated for 240 V AC single-phase operation, with a maximum of 440 V AC in multi-phase configurations, so it can sit on a 230/400 V three-phase panel as a single-pole branch protector. Sealable design means you can lock the toggle with a seal wire to prevent unauthorized reset, a common requirement for retail or public-access panels.

Single-module width (18 mm) — one slot in a distribution board. Depth of 76 mm with 70 mm installation depth means it clears most shallow enclosures. Mounting position any — horizontal, vertical, upside-down; no derating needed for orientation. The terminal design accepts supplementary devices like shunt trips or auxiliary contacts, so you can add remote trip or status feedback without swapping the breaker.

Frequently asked questions

What is the breaking capacity of 5SJ6116-7RC?

Rated 6 kA per EN 60898 at 240 V AC — sufficient for most commercial sub-distribution boards but not for high-capacity industrial buswork.

Where can I buy 5SJ6116-7RC?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SJ6116-7RC drop into a panel specified for 5SL4363-7?

No — 5SL4363-7 is a 3-pole, 3-module-width (54 mm) breaker with a 10 kA rating. The 5SJ6116-7RC is a single-pole, 18 mm wide unit. They share the same 76 mm depth and DIN-rail mount, but the pole count and width are different — you'd need to rewire the circuit and adjust the panel layout.