Siemens 5SJ6206-6RC SENTRON MCB, 2P, 6A, B Curve, 6kA

MPN5SJ6206-6RC

Siemens SENTRON 5SJ6206-6RC, 2-pole miniature circuit breaker, 6 A rated current, B tripping characteristic, 6 kA breaking capacity per EN 60898, 415 V AC, 2 modular width units (36 mm).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ6206-6RC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentretail line
5SJ6206-6RC — Electrical
ParameterValue
Number of poles2
5SJ6206-6RC — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SJ6206-6RC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SJ6206-6RC — Environmental
ParameterValue
Pollution degree2
5SJ6206-6RC — Specifications
ParameterValue
Energy Limitation ClassNo

Product details

The Siemens SENTRON 5SJ6206-6RC is a 2-pole miniature circuit breaker rated 6 A with a B tripping characteristic, breaking 6 kA per EN 60898 at 415 V AC. It occupies 2 modular width units (36 mm) on a DIN rail and is designated for retail-line branch circuit protection. The B curve trips between 3–5× rated current, making it a fit for resistive or general-purpose loads where inrush is minimal — think lighting circuits or small control transformers in a retail environment.

Key ratings and what they mean for fit

The 6 kA breaking capacity at 415 V AC per EN 60898 is the standard residential/commercial fault-interruption rating — adequate for most panelboards fed by a distribution transformer with typical available fault current under 6 kA. The 6 A continuous rating at 30 °C derates in higher ambient temperatures; the part is rated for operation from -40 °C to 75 °C, covering unheated enclosures and rooftop gear. Rated for 250 V AC single-phase and 440 V AC multi-phase operation, the 2-pole configuration handles split-phase or two-leg circuits. DC rating extends to 72 V, useful for control power or battery-backed loads. Overvoltage category III and pollution degree 2 suit fixed-installation panels in dry, non-conductive environments. Mechanical service life is 10,000 switching cycles typical. The breaker is halogen-free and silicon-free, and is sealable for tamper-proof installations.

Mounting and integration

Snap-on mounting to 35 mm DIN rail per EN 60715. Any mounting position is permitted. Installation depth is 70 mm behind the panel face; overall depth is 76 mm including the toggle. The IP20 rating with connected conductors means the busbar stabs and terminals are finger-safe only when wired — standard for distribution board use. Width of 36 mm (2 MW) fits standard modular enclosure cutouts.

Frequently asked questions

What is the depth of 5SJ6206-6RC?

Overall depth is 76 mm; installation depth behind the panel face is 70 mm.

What is the width of 5SJ6206-6RC?

Width is 36 mm, which corresponds to 2 modular width units on a standard DIN-rail enclosure.

Will 5SJ6206-6RC fit a panel designed for 5SJ6325-7RC?

No — the 5SJ6325-7RC is 54 mm wide (3 MW) versus 36 mm (2 MW) for the 5SJ6206-6RC. The depth and height are identical, but the width difference means the panel cutout and busbar arrangement must be verified before substitution.

MPN