Skip to main content
Siemens 5SJ6208-7 — 2-Pole MCB (DIN Rail)

Siemens 5SJ6208-7 SENTRON MCB, 2-pole, C, 8A, 400V AC

MPN5SJ6208-7

Siemens SENTRON 5SJ6 miniature circuit breaker, 2-pole, C-curve, 8 A rated, 400 V AC, 6 kA breaking capacity per EN 60898, 70 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SJ6208-7 — Electrical
ParameterValue
Number of poles2
5SJ6208-7 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage category3
5SJ6208-7 — Mechanical
ParameterValue
Installation depth70 mm
Mounting positionany
Protection degree (IP)IP20, with connected conductors

Product details

The Siemens 5SJ6208-7 is a 2-pole miniature circuit breaker from the SENTRON 5SJ6 family, rated 8 A at 400 V AC with a C tripping characteristic — meaning it is designed for moderate inrush loads such as small motor circuits, lighting banks, and control transformers where the starting current exceeds the nominal rating but stays within the C-curve magnetic trip window (5–10× In). The 2-pole configuration switches both line conductors, which is required for single-phase 230 V circuits in many regions or for two-wire 400 V line-to-line loads. The IP20 finger-safe terminals (with conductors connected) meet the basic touch-protection requirement inside an enclosed panel.

The terminal accepts solid or stranded conductors from 0.75 mm² up to 25 mm², which covers the full range of wire sizes typically used for an 8 A branch circuit (1.5 mm² to 4 mm² are common, but the 25 mm² upper limit accommodates a feed-through or daisy-chain application). Mounting position is unrestricted, so the breaker can be oriented vertically, horizontally, or upside-down on the rail without derating the thermal trip. The mechanical service life of 20 000 switching cycles is typical for an MCB in this class — adequate for routine isolation and fault clearing, but not intended for frequent load-break duty like a contactor.

Frequently asked questions

Will 5SJ6208-7 drop into a panel specified around 5SJ6216-6 without rewiring?

Yes, the mechanical footprint is identical — both are 2-pole, 2 width units, 70 mm depth, same terminal wire range (0.75–25 mm²) — so the 5SJ6208-7 fits the same DIN-rail position and busbar connection. No rewiring is needed for the physical swap, but the circuit protection values (8 A vs 16 A, C-curve vs B-curve) must match the load requirements.

Where can I buy 5SJ6208-7 and how is it quoted?

The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
5SJ6208-7