Skip to main content
Siemens 5SJ6210-6KS — 2-Pole MCB (DIN Rail)

Siemens 5SJ6210-6KS SENTRON MCB, 2P B 10A 6kA

MPN5SJ6210-6KS
Active

Siemens SENTRON miniature circuit breaker, 5SJ6210-6KS, 2-pole, B-curve, 10 A, 6 kA breaking capacity, 400 V AC, 70 mm installation depth, screwless outgoing terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SJ6210-6KS — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SJ6210-6KS — Electrical
ParameterValue
Number of poles2
5SJ6210-6KS — Protection
ParameterValue
Tripping characteristic classB
Overvoltage category3
5SJ6210-6KS — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SJ6210-6KS — Environmental
ParameterValue
Pollution degree2
5SJ6210-6KS — Specifications
ParameterValue
At AC rated value400 V
According to EN 60898 rated value6 kA
Energy Limitation Class3

Product details

The Siemens 5SJ6210-6KS is a SENTRON miniature circuit breaker (MCB) — 2-pole, B-curve, rated 10 A at 400 V AC, with a 6 kA breaking capacity certified to both EN 60898 and IEC 60947-2. Two-pole design (2P) switches both phase and neutral, common in single-phase final subcircuits where disconnection of both conductors is required.

Mounting and environment

Pollution degree 2 (non-conductive, occasional condensation) covers the typical control cabinet environment. Ambient storage range from -40 °C to +75 °C; operating ambient is -20 °C to +45 °C with periodic excursions to +55 °C at up to 95% humidity.

Frequently asked questions

Where can I buy 5SJ6210-6KS and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of 5SJ6210-6KS?

6 kA rated breaking capacity per EN 60898 and IEC 60947-2 at 400 V AC.

What is the difference between 5SJ6210-6KS and 5SJ6216-6?

The 5SJ6216-6 is the 16 A variant of the same 2-pole B-curve 5SJ6 platform — same footprint, same 6 kA breaking capacity, same terminal range. The only difference is the current rating (10 A vs 16 A). It drops into the same panel position without rewiring.

MPN
5SJ6210-6KS