Skip to main content
Siemens 5SJ6210-7RC — 2-Pole MCB (DIN Rail)

Siemens 5SJ6210-7RC SENTRON MCB, 2P 10A C-Curve 6kA

MPN5SJ6210-7RC

Siemens SENTRON 5SJ6210-7RC, MCB Retail line, 2-pole, 6 kA, 10 A, C characteristic.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SJ6210-7RC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentretail line
5SJ6210-7RC — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value415 V
5SJ6210-7RC — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SJ6210-7RC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SJ6210-7RC — Environmental
ParameterValue
Pollution degree2
At 30 °C rated value10 A
5SJ6210-7RC — Specifications
ParameterValue
At AC rated value10 A
According to EN 60898 rated value6 kA
With single-phase operation at AC rated value250 V
Energy Limitation ClassNo

Product details

The Siemens SENTRON 5SJ6210-7RC is a 2-pole miniature circuit breaker from the Retail line, rated 10 A with a C tripping characteristic and a 6 kA breaking capacity per EN 60898. It's a current-production part, so you're not chasing a last-time buy — this one stays in the catalog for new builds and panel spares alike.

At 10 A and 6 kA, this breaker handles residential or light commercial sub-feeds; the 6 kA SCCR per EN 60898 is adequate for most panelboards fed by a transformer of typical impedance. The 2-pole design switches both line and neutral on a single-phase circuit. Mounting position any simplifies panel layout — no derating needed if you install it sideways or upside down.

The breaker accepts supplementary devices like shunt trips, auxiliary contacts, and alarm switches — all from the SENTRON accessory range. If your panel already uses those add-ons, the 5SJ6210-7RC drops in without rewiring the accessory bus.

Frequently asked questions

Will 5SJ6210-7RC drop into a panel that was specified around 5SL4363-7 without rewiring?

No — the 5SL4363-7 is a 3-pole breaker with a 54 mm width, while the 5SJ6210-7RC is 2-pole at 36 mm. The DIN-rail mounting and depth are the same (76 mm), but the pole count and width differ, so you'd need to re-terminate the third phase and adjust the DIN-rail space.

What is 5SJ6210-7RC's listed depth?

The overall depth is 76 mm, with an installation depth of 70 mm.

MPN