Skip to main content
Siemens 5SJ6310-6 — 3-Pole MCB (DIN Rail)

Siemens 5SJ6310-6 SENTRON MCB, 3-Pole B 10A 6kA 400V

MPN5SJ6310-6

Siemens SENTRON 5SJ6 series, miniature circuit breaker, 3-pole, B-characteristic, 10 A, 6 kA breaking capacity per EN 60898, 400 V AC.

$61.89Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SJ6310-6 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
5SJ6310-6 — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 608986 kA
Breaking capacity per IEC 60947-26 kA
Overvoltage category3
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SJ6310-6 — Electrical
ParameterValue
Rated frequency50 Hz
5SJ6310-6 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SJ6310-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturePeriodically +55°C, max. 95% humidity

Product details

Siemens SENTRON 5SJ6310-6 — 3-pole B-curve MCB, 10 A, 6 kA

Mounting position is unrestricted, and the touch-protected terminals accept conductors up to the rated cross-section per the datasheet. The IP20 rating applies with conductors connected — standard for enclosed panel use.

The energy limitation class of 3 means it restricts let-through energy during a fault — relevant for downstream component protection and cable thermal stress. For DC circuits, the breaker is rated up to 60 V, which covers 48 V control buses and telecom-style supplies. The AC/DC voltage type means the same unit handles both, though the breaking capacity on DC is typically lower — verify the DC performance curve if the circuit is purely DC.

Environmental and storage ratings

Periodic ambient temperature up to +55 °C with 95% humidity is within the operating envelope, though continuous operation near the upper limit should be checked against the thermal derating curve. Mechanical service life is rated at 20,000 switching cycles typical — sufficient for normal panel switching and isolation duty. Vibration resistance per IEC 60068-2-6 is 50 m/s² at 25 to 150 Hz and 60 m/s² at 10 to 150 Hz, which covers most industrial panel vibration profiles without additional damping.

Frequently asked questions

What is the breaking capacity of the 5SJ6310-6?

The 5SJ6310-6 is rated 6 kA per EN 60898 and also 6 kA per IEC 60947-2 at 400 V AC.

What is the difference between the 5SJ6310-6 and the 2-pole 5SJ6220-6?

The 5SJ6310-6 is a 3-pole breaker rated 10 A, while the 5SJ6220-6 is a 2-pole breaker rated 20 A. Both share the same B-curve, 6 kA breaking capacity, 70 mm depth, and SENTRON 5SJ6 platform. The 5SJ6310-6 occupies 3 width units versus 2 for the 5SJ6220-6. A panel wired for a 2-pole breaker cannot accept the 3-pole unit without rewiring and freeing an additional DIN-rail position.

Where can I buy the 5SJ6310-6?

The 5SJ6310-6 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What is the storage temperature range for the 5SJ6310-6?

The storage temperature range is -40 °C to +75 °C.

MPN