Skip to main content
Siemens 5SJ6316-6 — 3-Pole MCB (DIN Rail)

Siemens 5SJ6316-6 SENTRON MCB, 3-Pole, B Curve, 16A, 6kA

MPN5SJ6316-6

Siemens SENTRON 5SJ6 series, miniature circuit breaker, 3-pole, B tripping characteristic, 16 A rated current, 6 kA breaking capacity, 400 V AC, 70 mm installation depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SJ6316-6 — Identification
ParameterValue
Design / model code5SJ6
Brand nameSENTRON
Number of poles3
5SJ6316-6 — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 608986 kA
Breaking capacity per IEC 60947-26 kA
Overvoltage category3
IP protection classIP20, with connected conductors
5SJ6316-6 — Electrical
ParameterValue
Rated frequency50 Hz
5SJ6316-6 — Mechanical
ParameterValue
Mounting positionany
Installation depth70 mm
SealableYes
5SJ6316-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturePeriodically +55°C, max. 95% humidity

Product details

Siemens 5SJ6316-6 — 3-Pole B-Curve MCB for 16 A Branch Circuits

The Siemens 5SJ6316-6 is a 3-pole miniature circuit breaker from the SENTRON 5SJ6 series, rated 16 A with a B tripping characteristic and a 6 kA breaking capacity per EN 60898. The B curve means magnetic trip occurs between 48 A and 80 A — fast enough to clear a hard short but forgiving enough to avoid nuisance trips on moderate inrush. For DC circuits, the maximum rated voltage is 60 V, so it can serve DC sub-circuits within that limit.

Integration — DIN-Rail Mount, 70 mm Depth, Any Position

Terminal capacity of 25 mm² stranded covers incoming feeder conductors up to 4 AWG. Touch protection is integrated (product feature: Yes). Periodic exposure to +55 °C at up to 95% humidity is permissible, but continuous operation above 45 °C requires derating per the thermal curve. Vibration resistance is 50 m/s² at 25–150 Hz and 60 m/s² at 10–150 Hz per IEC 60068-2-6.

Compliance & Standards — EN 60898, IEC 60947-2, Overvoltage Category III

The dual rating means it is certified for use in residential/commercial boards (EN 60898) and industrial control panels (IEC 60947-2) — the same 6 kA figure applies in both contexts. Overvoltage category III confirms suitability for fixed-installation distribution boards downstream of the main panel. Energy limiting class 3 means the breaker limits let-through energy to a low level during a fault, reducing stress on downstream components. Mechanical service life is 20 000 switching cycles typical — adequate for branch-circuit protection where switching is infrequent (not a load-switching device).

Frequently asked questions

What is the breaking capacity of 5SJ6316-6?

6 kA per both EN 60898 and IEC 60947-2. This is the interrupting rating at 400 V AC for a 3-pole breaker with B characteristic.

What conductor sizes does 5SJ6316-6 accept?

Solid conductors from 0.75 mm² to 25 mm²; stranded conductors from 0.75 mm² to 25 mm². The terminals are sealable for tamper-proof installations.

Where can I buy 5SJ6316-6?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit a request for a firm quote with lead time.

Will 5SJ6316-6 drop into a panel specified for 5SL4120-7CC?

Not without panel changes. The 5SL4120-7CC is a 1-pole, C-curve, 20 A, 10 kA breaker with 18 mm width. The 5SJ6316-6 is 3-pole, B-curve, 16 A, 6 kA, occupying 3 width units (54 mm). The footprint, pole count, and protection characteristics are different — a full coordination review is needed.

MPN
5SJ6316-6