Siemens 5SJ6316-7 — 3-Pole MCB (DIN Rail)

Siemens 5SJ6316-7 SENTRON MCB, 3-Pole C 16A 6kA

MPN5SJ6316-7

Siemens SENTRON 5SJ6, miniature circuit breaker, 3-pole, C-curve, 16 A, 400 V AC, 6 kA breaking capacity per EN 60898, 70 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SJ6316-7 — Identification
ParameterValue
Design / model code5SJ6
Brand nameSENTRON
Number of poles3
5SJ6316-7 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 608986 kA
Breaking capacity per IEC 60947-26 kA
Overvoltage category3
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SJ6316-7 — Electrical
ParameterValue
Rated frequency50 Hz
5SJ6316-7 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SJ6316-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturePeriodically +55°C, max. 95% humidity

Product details

Siemens 5SJ6316-7 — 3-pole C-curve MCB, 16 A, 6 kA

The Siemens 5SJ6316-7 is a SENTRON miniature circuit breaker, 3-pole, with a C-curve tripping characteristic, rated at 16 A at 400 V AC. Its 6 kA breaking capacity per EN 60898 (and matching 6 kA per IEC 60947-2) suits it for final subcircuit protection in commercial and light industrial panels — think lighting, socket outlets, and small motor loads where the fault current at the board stays under that threshold. The 5SJ6 design carries a 70 mm installation depth and occupies 3 modular width units on the DIN rail.

The 16 A rating at 400 V AC three-phase covers a 3-pole load; the same breaker also carries a DC rating of 60 V maximum, so it can serve a 60 V DC control bus if needed. Breaking capacity of 6 kA per both EN 60898 and IEC 60947-2 means it will safely interrupt a fault up to that level without welding its contacts. The 440 V insulation voltage and overvoltage category 3 confirm it is built for fixed-installation mains distribution.

Deployment context — panel integration and environment

For environmental tolerance: storage range from -40 °C to +75 °C, periodic ambient up to +55 °C at 95 % humidity. Halogen-free and silicon-free construction matters in clean-room or corrosive-plant environments where outgassing can foul contacts or optics.

Frequently asked questions

What is the breaking capacity of 5SJ6316-7?

The 5SJ6316-7 has a 6 kA breaking capacity per EN 60898 and also 6 kA per IEC 60947-2.

What temperature range does 5SJ6316-7 handle?

Storage temperature range is -40 °C to +75 °C.

Where can I buy 5SJ6316-7?

The 5SJ6316-7 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SJ6316-7 drop into a panel specified around 5SJ6463-7 without rewiring?

The 5SJ6316-7 (3-pole, 16 A) and the 5SJ6463-7 (4-pole, 63 A) share the same 70 mm depth, DIN-rail mounting, and SENTRON 5SJ6 design, but the 5SJ6463-7 is a 4-pole unit occupying 4 modular width units versus 3 for the 3-pole 5SJ6316-7. The panel must have the wider slot and the neutral conductor path to accept the 4-pole unit, so a direct drop-in without rewiring is not possible unless the panel was already wired for 4-pole.

MPN