Skip to main content
Siemens 5SJ6320-7 — 3-Pole MCB (DIN Rail)

Siemens 5SJ6320-7 SENTRON MCB, 3P C-curve 20A 6kA

MPN5SJ6320-7

Siemens SENTRON 5SJ6 series, miniature circuit breaker 5SJ6320-7, 3-pole, C-curve, 20 A rated current, 400 V AC, 6 kA breaking capacity, 70 mm installation depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SJ6320-7 — Identification
ParameterValue
Design / model code5SJ6
Brand nameSENTRON
Number of poles3
5SJ6320-7 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 608986 kA
Breaking capacity per IEC 60947-26 kA
Overvoltage category3
IP protection classIP20, with connected conductors
Pollution degree2
5SJ6320-7 — Electrical
ParameterValue
Rated frequency50 Hz
5SJ6320-7 — Mechanical
ParameterValue
Mounting positionany
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SJ6320-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturePeriodically +55°C, max. 95% humidity

Product details

The Siemens SENTRON 5SJ6320-7 is a 3-pole miniature circuit breaker from the 5SJ6 series, rated 20 A at 400 V AC with a C-curve tripping characteristic.

Panel fit and environmental range

Mounting position is unrestricted, which simplifies layout in crowded enclosures.

The C-curve trips at 5 to 10 times rated current (100–200 A magnetic trip), so it handles the starting surge of a 7.5 kW motor or a bank of fluorescent fittings without nuisance trips. For DC circuits, the maximum rated voltage is 60 V, which limits its use to low-voltage DC control circuits or battery-backed loads. Pollution degree 2 (non-conductive dust, occasional condensation) covers typical industrial and commercial environments.

Construction and compliance details

Touch protection is integrated on the line-side terminals. Energy limiting class 3 provides moderate current limitation during a short circuit, reducing let-through energy to downstream equipment. Vibration resistance tested to IEC 60068-2-6 at 50 m/s² over 25 to 150 Hz, with a higher 60 m/s² over 10 to 150 Hz — suitable for installation on machinery or in transport applications.

Frequently asked questions

What is the breaking capacity of 5SJ6320-7?

6 kA, certified to both EN 60898 and IEC 60947-2 at 400 V AC. This covers standard commercial and light industrial sub-distribution where fault current stays under that level.

Will 5SJ6320-7 drop into a panel specified around 5SL4120-7CC?

No — the 5SJ6320-7 is a 3-pole breaker occupying 3 width units (54 mm), while the 5SL4120-7CC is a 1-pole unit at 1 width unit (18 mm). They are not form-fit interchangeable. For a 3-pole replacement within the SENTRON family, the 5SL4363-7 (3-pole, C-curve, 63 A, 10 kA) shares the same 3-width-unit footprint and 70 mm installation depth, but its higher current and breaking capacity may require coordination review upstream.

Where can I buy 5SJ6320-7?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm price and lead time.

What is the operating temperature range for 5SJ6320-7?

Rated for -40 °C to 75 °C ambient, with periodic exposure to +55 °C and up to 95% humidity. This covers unheated enclosures and outdoor-rated cabinets in most climates.

MPN
5SJ6320-7