Siemens 5SJ6463-6 — 4-Pole MCB (DIN Rail)

Siemens 5SJ6463-6 SENTRON MCB, 4-Pole B 63A 6kA

MPN5SJ6463-6

Siemens SENTRON 5SJ6 series, miniature circuit breaker, 4-pole, B tripping characteristic, 63 A rated current, 6 kA breaking capacity, 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SJ6463-6 — Identification
ParameterValue
Type / order code5SJ6
Brand nameSENTRON
5SJ6463-6 — Ratings
ParameterValue
Number of poles4
Pole configuration4
Rated current (In), AC63 A
Rated voltage, DC (max.)60 V
Voltage typeAC/DC
Rated frequency50 Hz
5SJ6463-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-26 kA
Overvoltage category3
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SJ6463-6 — Mechanical
ParameterValue
Width in modular units4
Installation depth70 mm
Mounting positionany
SealableYes
5SJ6463-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Periodically +55°C, max. 95% humidity
5SJ6463-6 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)20 000

Product details

What this 4-pole B-curve 63 A MCB delivers

The Siemens SENTRON 5SJ6463-6 is a 4-pole miniature circuit breaker rated 63 A at 400 V AC, with a B tripping characteristic and a 6 kA breaking capacity certified to both EN 60898 and IEC 60947-2.

The 6 kA rated short-circuit capacity (Icn per EN 60898, Icu per IEC 60947-2) is the standard residential and light-commercial fault level across most of Europe and Asia. At 400 V three-phase, 6 kA prospective fault current covers the majority of distribution boards downstream of a larger upstream breaker or transformer. The energy limiting class of 3 means this MCB restricts let-through energy enough to protect downstream wiring and connected equipment under short-circuit conditions — a coordination detail worth verifying against the upstream protective device's let-through curve if the panel feeds sensitive electronics.

Installation and wiring

The terminal accepts solid or stranded conductors from 0.75 mm² up to 25 mm², which covers everything from 1.5 mm² lighting tails to 16 mm² subfeed cables. The IP20 rating (with conductors connected) is standard for enclosed distribution boards; no special sealing is required inside a panel. Touch protection is built into the terminals, so accidental contact during maintenance is prevented as long as conductors are properly terminated.

For a BOM line that needs this exact 4-pole 63 A B-curve MCB, the 5SJ6463-6 is the correct order code — no parametric substitute is required.

Frequently asked questions

Where can I buy the 5SJ6463-6 and get a price?

The 5SJ6463-6 is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm current availability and pricing.

What is the difference between the 5SJ6463-6 and the 5SJ6463-7?

Both are 4-pole 63 A MCBs with identical 6 kA breaking capacity, 400 V rating, and 70 mm depth. The only difference is the tripping characteristic: the 5SJ6463-6 uses a B-curve (3–5× In), while the 5SJ6463-7 uses a C-curve (5–10× In). The B-curve is preferred for resistive loads and general distribution; the C-curve handles higher inrush from motor or transformer loads. They are mechanically interchangeable on the same DIN rail.

What wire sizes does the 5SJ6463-6 accept?

The terminals accept solid or stranded conductors from 0.75 mm² up to 25 mm².

What compliance documentation is available for the 5SJ6463-6?

The MCB is certified to EN 60898 and IEC 60947-2 for breaking capacity, and carries an IP20 protection class. It is halogen-free and silicon-free. Standard Siemens SENTRON documentation includes CE declaration of conformity and RoHS compliance information.