Siemens 5SJ6520-7KS SENTRON MCB, 1P+N, C-curve, 20 A, 6 kA

MPN5SJ6520-7KS
Active

Siemens SENTRON 5SJ6 miniature circuit breaker, 1-pole+N, C-curve, 20 A, 6 kA acc. to EN 60898, 230 V AC, 2 MW, screwless terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ6520-7KS — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityResidential buildings/infrastructure
5SJ6520-7KS — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage category3
5SJ6520-7KS — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SJ6520-7KS — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The 5SJ6520-7KS is a 1P+N SENTRON miniature circuit breaker rated 20 A with a C-curve tripping characteristic — magnetic trip between 5× and 10× In, so it handles moderate inrush from lighting or small motor loads without nuisance trips. Breaking capacity is 6 kA per both EN 60898 and IEC 60947-2, meaning it can safely interrupt a fault current up to 6 kA at 230 V AC without welding its contacts. The neutral pole switches simultaneously with the phase, which is required for single-phase final subcircuits where you need to isolate both conductors for safe maintenance.

Frequently asked questions

What is the breaking capacity of 5SJ6520-7KS?

6 kA rated per both EN 60898 and IEC 60947-2 at 230 V AC. That covers the fault-current duty of most residential and light-commercial distribution boards.

Does 5SJ6520-7KS switch the neutral?

Yes, it is a 1P+N design with neutral conductor switching. Both phase and neutral poles open simultaneously, isolating the load completely for safe maintenance.

What terminals does the 5SJ6520-7KS use?

Screwless (push-in) outgoing terminals. No screwdriver required for solid or ferruled stranded conductors — speeds wiring in repetitive panel builds.

Where can I buy 5SJ6520-7KS and what is the lead time?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for the current supply posture.

Will 5SJ6520-7KS fit a panel designed for 5SL6550-7BB?

Yes — both are 2 MW wide (36 mm), same 76 mm depth, same DIN-rail mounting. The 5SJ6520-7KS is rated 20 A C-curve; the 5SL6550-7BB is 50 A C-curve. If the panel busbar and load wiring are sized for 50 A, dropping in a 20 A MCB is fine. If you need the higher ampacity, stay with the 5SL series.