Siemens 5SJ6563-7 — 1-Pole MCB (DIN Rail)

Siemens 5SJ6563-7 SENTRON MCB, 63A 1P+N C-Curve, 6kA

MPN5SJ6563-7

Siemens SENTRON 5SJ6 series, miniature circuit breaker 5SJ6563-7, 1P+N, 63 A, C characteristic, 6 kA, 240 V AC, 2 width units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SJ6563-7 — Identification
ParameterValue
Product designationMiniature circuit breakers
Brand nameSENTRON
Number of poles2
5SJ6563-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Overvoltage category3
5SJ6563-7 — Mounting & Connection
ParameterValue
Mounting positionany
Installation depth70 mm
SealableYes
5SJ6563-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

The 1P+N configuration switches the line conductor and provides a switched neutral. The 2 width units occupy two modular slots on a standard DIN rail. The sealable feature allows lockout/tagout compliance.

Deployment context

Installation depth is 70 mm, which fits typical distribution board enclosures. Ambient temperature range is -20 to +45 °C, with periodic excursions to +55 °C at up to 95% humidity. That covers most indoor panel environments, but if your panel sits near a furnace or in direct sun, derate the 63 A per the manufacturer's thermal curve above 40 °C.

The 5SJ6563-7 carries a halogen-free and silicon-free construction, which matters for environments where outgassing can contaminate contacts or optics — think clean rooms or sealed enclosures. Vibration resistance is tested per IEC 60068-2-6 at 50 m/s² from 25 to 150 Hz and 60 m/s² from 10 to 150 Hz, so it holds up on machinery or in mobile installations. Mechanical service life is 20 000 switching cycles typical — adequate for normal branch-circuit duty; if you're cycling it daily for load shedding, consider a contactor instead.

Frequently asked questions

Will 5SJ6563-7 drop into a panel specified around 5SL4120-7CC?

No, not without rewiring. The 5SL4120-7CC is a 1-pole (1P) 20 A breaker occupying 1 width unit. The 5SJ6563-7 is 1P+N (switched neutral) at 63 A and takes 2 width units. The terminal sizes differ, and the neutral switching changes the wiring scheme. You would need to re-terminate the neutral and adjust the DIN rail space.

MPN
5SJ6563-7