Skip to main content
Siemens 5SL1110-6MB — 1-Pole MCB (DIN Rail)

Siemens 5SL1110-6MB SENTRON MCB, 1P, B Curve, 10A, 3kA

MPN5SL1110-6MB

Siemens SENTRON 5SL1110-6MB miniature circuit breaker, 1-pole, B characteristic, 10 A, 230/400 V AC, 3 kA breaking capacity per IEC 60947-2, 1 MWU.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL1110-6MB — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityResidential buildings/infrastructure
5SL1110-6MB — Electrical & Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SL1110-6MB — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL1110-6MB — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SL1110-6MB is a 1-pole miniature circuit breaker with a B tripping characteristic, rated at 10 A for 230/400 V AC circuits.

The B-curve trips between 3 and 5 times rated current — 30 A to 50 A for this 10 A unit — so it is the right choice for resistive and general-purpose loads where inrush is low. If your panel's prospective short-circuit current exceeds 3 kA at the point of installation, step up to the 4.5 kA or 6 kA variants in the same SENTRON 5SL family. Single-pole construction means it switches only the phase conductor. The neutral is not broken. That is standard for single-phase branch circuits in TN and TT systems. For multi-phase applications, the breaker is rated up to 440 V AC between poles. Depth is 76 mm, with 70 mm required behind the panel surface for the body.

Installation notes

Mounts in any position on the DIN rail. Sealable with a lead or wire seal to prevent tampering — useful for metering or tenant sub-circuits. In a densely packed enclosure, that heat adds up — account for it in the thermal budget if you are grouping multiple breakers side by side.

DC capability

Rated for DC circuits up to 72 V maximum. This is a single-pole DC rating — for higher DC voltages you would need series-connected poles or a dedicated DC-rated breaker. The B curve's magnetic trip threshold is higher on DC due to the lack of zero-crossing, so verify coordination with your DC source impedance.

Frequently asked questions

What is the breaking capacity of the 5SL1110-6MB?

The 5SL1110-6MB has a 3 kA breaking capacity according to IEC 60947-2 at 230/400 V AC.

Will the 5SL1110-6MB drop into a panel specified for the 5SL3116-6MB?

Yes, both share the same 18 mm width, 76 mm depth, and DIN-rail mounting. The 5SL3116-6MB is a 16 A B-curve breaker with a 4.5 kA breaking capacity per EN 60898 — the 5SL1110-6MB is the 10 A, 3 kA version. No rewiring needed for the same footprint.

Where can I buy the 5SL1110-6MB?

The 5SL1110-6MB is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the 5SL1110-6MB rated for on DC?

It is rated for DC circuits up to 72 V maximum.

MPN
5SL1110-6MB