Siemens 5SL1263-7MB — 2-Pole MCB (DIN Rail)

Siemens 5SL1263-7MB SENTRON MCB, 2P C-Curve 63A 3kA

MPN5SL1263-7MB

Siemens SENTRON 5SL1263-7MB, 2-pole miniature circuit breaker, C-curve, 63 A rated current, 3 kA breaking capacity (IEC 60947-2), 230/400 V AC, 36 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL1263-7MB — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL1263-7MB — Electrical
ParameterValue
Number of poles2
5SL1263-7MB — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL1263-7MB — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL1263-7MB — Environmental
ParameterValue
Pollution degree2

Product details

The Siemens 5SL1263-7MB is a SENTRON 5SL series miniature circuit breaker, 2-pole, C-curve, rated 63 A at 30 °C. Breaking capacity is 3 kA per IEC 60947-2 — that's the fault current it can safely interrupt without welding contacts or cascading upstream. The C-curve (5-10x In) means it handles moderate inrush from motor starters or transformer loads without nuisance tripping, while still clearing short circuits fast enough for most residential and light-commercial panels.

Panel fit and mounting

Width is 36 mm (2 modular units), depth 76 mm, installation depth 70 mm. Snaps onto standard DIN rail — any mounting position works, no derating for orientation. IP20 with conductors connected, so it's panel-internal only; no washdown exposure. Halogen-free and silicon-free construction matters if this goes into a clean room or a zone where off-gassing from a fault could damage nearby electronics.

What the ratings mean for your panel

The 3 kA breaking capacity (IEC 60947-2) is the ceiling for fault clearing — if your available fault current at the panel exceeds that, you need an upstream current-limiting device or a higher-rated breaker. Overvoltage category III and pollution degree 2 are standard for fixed-installation distribution boards. Mechanical service life is 4,000 switching cycles — fine for branch-circuit protection where it trips rarely, but not for frequent switching duty. The sealable design lets a panel builder or inspector lock the toggle position after commissioning.

Frequently asked questions

What is the breaking capacity of 5SL1263-7MB?

3 kA per IEC 60947-2. That's the maximum fault current it can safely interrupt at 230/400 V AC.

Will 5SL1263-7MB drop into a panel specified for 5SL3205-7MB?

Yes — same 36 mm width, same 76 mm depth, same DIN-rail mounting. The 5SL3205-7MB is a 0.5 A C-curve; this is 63 A C-curve. Same footprint, different current rating. No rewiring needed if the busbar and load conductors are sized for 63 A.

How do I get current pricing and availability for 5SL1263-7MB?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — submit an RFQ for a firm quote.