Siemens 5SL1301-7MB — 3-Pole MCB (DIN Rail)

Siemens 5SL1301-7MB SENTRON MCB, 3P C-Curve 1A 3kA

MPN5SL1301-7MB

Siemens SENTRON 5SL1301-7MB miniature circuit breaker, 3-pole, C-curve, 1 A rated, 3 kA breaking capacity per IEC 60947-2, 230/400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL1301-7MB — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL1301-7MB — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per IEC 60947-23 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree2
5SL1301-7MB — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)0.96 W
Rated voltage (AC, single-phase)253 V
5SL1301-7MB — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SL1301-7MB — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL1301-7MB is a 3-pole miniature circuit breaker from the SENTRON series, rated 1 A with a C tripping characteristic. It protects branch circuits in residential and light commercial infrastructure panels, interrupting faults up to 3 kA per IEC 60947-2 at 230/400 V AC.

For a 3-pole breaker on a 230/400 V three-phase system, that's 1 A per phase — enough for a small control transformer or a few pilot lights, not for motor or heater circuits. The 3 kA breaking capacity per IEC 60947-2 tells you the breaker can safely interrupt a fault current up to 3 kA without welding contacts or cascading failure upstream. In a residential panel with typical available fault current below 3 kA, that's adequate; if your service entrance has higher fault current, you'll need a breaker with a higher interrupting rating.

Panel integration and physical fit

The 5SL1301-7MB snaps onto a standard DIN rail (mounting position any) and occupies 3 modular width units (54 mm wide). Depth is 76 mm, installation depth 70 mm — it clears a standard 80 mm deep enclosure.

Frequently asked questions

Where can I buy 5SL1301-7MB and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
5SL1301-7MB