Siemens 5SL1306-7MB — 3-Pole MCB (DIN Rail)

Siemens 5SL1306-7MB SENTRON MCB, 3P C-6A, 3kA

MPN5SL1306-7MB

Siemens SENTRON 5SL1306-7MB, miniature circuit breaker, 3-pole, C-curve, 6 A rated, 3 kA breaking capacity (IEC 60947-2), 230/400 V AC, 50/60 Hz.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SL1306-7MB — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL1306-7MB — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per IEC 60947-23 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree2
5SL1306-7MB — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)0.9 W
Mechanical service life (operating cycles, typ.)4 000
Rated voltage (AC, single-phase)253 V
5SL1306-7MB — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SL1306-7MB — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

What it is and what it does

The Siemens 5SL1306-7MB is a SENTRON miniature circuit breaker (MCB) — a 3-pole, C-curve device rated 6 A at 230/400 V AC, 50/60 Hz. It protects branch circuits in residential and light commercial panels against overloads and short circuits. The C-curve trips between 5 and 10 times rated current, so it handles moderate inrush from small motors or transformers without nuisance tripping, while still clearing a hard fault. Breaking capacity is 3 kA per IEC 60947-2 — enough for most domestic and small commercial distribution boards where the prospective fault current stays under that threshold. For panels with higher fault current, the 5SL4363-7 sibling offers 10 kA.

DIN-rail fit and panel integration

Snaps onto standard 35 mm DIN rail in any mounting position. Takes 3 modular width units (54 mm wide), with 76 mm depth and 90 mm height. Installation depth is 70 mm — the extra 6 mm accounts for the front toggle and terminal clearance. Sealable cover is standard, so you can lock the setting after commissioning. IP20 with connected conductors — fine inside a closed panel; not rated for washdown or outdoor exposure. Pollution degree 2 and overvoltage category III are typical for fixed-installation distribution boards.

Material and compliance

Halogen-free and silicon-free construction — relevant for panels in clean rooms or areas where outgassing must be minimized. Mechanical service life is 4,000 operating cycles typical; power loss per pole is 0.9 W at rated current in hot state.

Frequently asked questions

What is the breaking capacity of the 5SL1306-7MB?

3 kA per IEC 60947-2. For panels needing higher fault-current withstand, the sibling 5SL4363-7 offers 10 kA.

Where can I buy the 5SL1306-7MB?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will the 5SL1306-7MB drop into a panel specified for the 5SL4363-7?

Yes — both share the same 3-pole, 3-module-width DIN-rail footprint, same 76 mm depth, 54 mm width, and 90 mm height. The key difference is breaking capacity: 3 kA vs 10 kA. No rewiring needed if the panel's fault current is within the lower rating.

MPN
5SL1306-7MB