Skip to main content
Siemens 5SL1310-7MB — 3-Pole MCB (DIN Rail)

Siemens 5SL1310-7MB SENTRON MCB, C-Curve 10A 3-Pole 3kA

MPN5SL1310-7MB

Siemens SENTRON 5SL1310-7MB, miniature circuit breaker, 3-pole, C-curve 10 A, 230/400 V AC, 3 kA per IEC 60947-2, 3 MW units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SL1310-7MB — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL1310-7MB — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per IEC 60947-23 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree2
5SL1310-7MB — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.2 W
Mechanical service life (operating cycles, typ.)4 000
Rated voltage (AC, single-phase)253 V
5SL1310-7MB — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SL1310-7MB — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL1310-7MB is a SENTRON miniature circuit breaker (MCB) — a 3-pole, 10 A, C-curve device rated for 230/400 V AC with a 3 kA breaking capacity per IEC 60947-2.

The C-curve trips between 5 and 10 times rated current (50–100 A for this 10 A unit), which is the standard choice for general-purpose loads like lighting, socket outlets, and small appliances where moderate inrush is expected. The 3 kA breaking capacity per IEC 60947-2 tells you it can safely interrupt a fault current up to 3 kA at 400 V; that's sufficient for most residential and light commercial sub-distribution boards, but if your available fault current at the panel exceeds 3 kA you'll need an upstream current-limiting device or a higher-rated MCB. It's rated for 230 V single-phase and 400 V three-phase, 50/60 Hz, and also carries a DC rating of 72 V maximum — useful for some DC sub-circuits, but verify polarity and arc extinction for DC loads. The mechanical service life is 4,000 operating cycles typical, which is standard for a residential-grade MCB; for high-cycle applications (frequent switching) consider an industrial-rated breaker.

Dimensions are 90 mm height, 54 mm width (3 MW), 76 mm depth, with an installation depth of 70 mm.

Frequently asked questions

Where can I buy 5SL1310-7MB and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will 5SL1310-7MB drop into a panel that was specified around 5SL4363-7 without rewiring?

Yes, the 5SL1310-7MB shares the same 76 mm depth, 54 mm width (3 MW), 90 mm height, and DIN-rail mounting as the 5SL4363-7, so it is a mechanical drop-in. The key difference is breaking capacity: the 5SL1310-7MB is rated 3 kA per IEC 60947-2, while the 5SL4363-7 is rated 10 kA per both EN 60898 and IEC 60947-2. If the panel's available fault current exceeds 3 kA, the 5SL1310-7MB is not a suitable substitute.

What compliance documentation does this brand provide for 5SL1310-7MB?

As a SENTRON product, the 5SL1310-7MB is designed to meet IEC 60947-2 and EN 60898 standards for miniature circuit breakers. It carries CE marking for the European market. Specific RoHS, REACH, and UL documentation should be confirmed at time of order — we can provide manufacturer declarations upon request with an RFQ.

MPN
5SL1310-7MB