Skip to main content
Siemens 5SL1370-7MB — 3-Pole MCB (DIN Rail)

5SL1370-7MB SENTRON MCB, 70A 3P C-Curve 3kA

MPN5SL1370-7MB

Siemens SENTRON 5SL1370-7MB, 3-pole miniature circuit breaker, 70 A, C-curve, 3 kA breaking capacity (IEC 60947-2), 230/400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL1370-7MB — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL1370-7MB — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per IEC 60947-23 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree2
5SL1370-7MB — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)6.3 W
Mechanical service life (operating cycles, typ.)4 000
Rated voltage (AC, single-phase)253 V
5SL1370-7MB — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SL1370-7MB — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The C-curve means it holds through motor inrush and capacitor charging without nuisance trips — typical for general-purpose lighting and socket circuits. The 3 kA breaking capacity (IEC 60947-2) is the hard ceiling: if the panel's prospective short-circuit current exceeds that, this breaker won't clear the fault safely. Stick to residential or small commercial sub-distribution where the utility transformer is sized for it. At 70 A on a 3-pole frame, each pole dissipates 6.3 W in hot state — that's noticeable in a crowded enclosure. Plan for ventilation or derating if other devices are packed tight.

Three modular-width units (54 mm wide) snap onto standard DIN rail. Mount in any position;

Frequently asked questions

Where can I buy 5SL1370-7MB and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SL1370-7MB drop into a panel specified around 5SL4363-7?

Both share the same 54 mm width (3 MW), 76 mm depth, and DIN-rail mounting, so the footprint is identical. The key difference is breaking capacity: 5SL4363-7 is rated 10 kA per EN 60898, while this unit is 3 kA per IEC 60947-2. If the panel's fault level is above 3 kA, the 5SL4363-7 is the correct choice.

What compliance documentation does Siemens provide for 5SL1370-7MB?

The part is halogen-free and silicon-free, and designed to IEC 60947-2. Standard Siemens declarations (CE, UKCA) and material compliance (RoHS, REACH) are available on request.

MPN
5SL1370-7MB