Skip to main content
Siemens 5SL3006-7 — 1-Pole MCB (DIN Rail)

Siemens 5SL3006-7 SENTRON MCB, C-Curve 1P+N, 4.5 kA

MPN5SL3006-7
Active

Siemens SENTRON 5SL3006-7, miniature circuit breaker compact, C-curve, 1P+N, 4.5 kA breaking capacity per IEC/EN 60898-1, 18 mm width, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SL3006-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Pole design1P+N
Application suitabilityResidential buildings/infrastructure
5SL3006-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SL3006-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodDIN rail
Combined terminal, topNo
Combined terminal, bottomNo
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL3006-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

What this MCB does and where it fits

The Siemens 5SL3006-7 is a SENTRON miniature circuit breaker with a C-curve trip characteristic, meaning it's built for moderate inrush loads like small motor starters, lighting banks, and transformer primaries — the kind of load where you need the magnetic trip to hold off for a short pulse without nuisance tripping. It's a 1P+N design, so it switches both the line and the neutral, and it's rated for 230 V AC (single-phase) with a breaking capacity of 4.5 kA per IEC/EN 60898-1 and GB/T 10963.1. The 18 mm width (one modular unit) snaps onto a standard DIN rail, and the mounting position is unrestricted — you can orient it any way the panel layout demands.

Panel integration notes

The 5SL3006-7 installs in any DIN-rail enclosure with a 70 mm installation depth — the overall depth is 76 mm, so leave clearance for wiring and the front toggle. It's rated IP20 with connected conductors, which is standard for enclosed panel mount — not for wet or washdown areas. The terminals accept supplementary devices (auxiliary contacts, shunt trips, alarm switches) if you need remote status or trip indication.

Environmental and compliance details

Operating temperature range is -25 °C to 45 °C at up to 85% relative humidity, with derating above 45 °C up to 60 °C at 43% rF. The housing is halogen-free and silicon-free, which matters for panels in clean-room or corrosive-gas environments where outgassing can cause contact issues. It's rated for overvoltage category III and pollution degree 2, so it's suited for fixed-installation distribution boards in residential and light-commercial infrastructure.

Frequently asked questions

What is the closest functional second-source to 5SL3006-7?

The 5SY6006-7 is a peer in the same SENTRON family with a similar C-curve and 1P+N configuration, but it's a higher-breaking-capacity variant — verify the interrupting rating your application requires before substituting.

Will 5SL3006-7 drop into a panel specified around 5SY6006-7 without rewiring?

Both share the same 18 mm width and DIN-rail mounting, so the physical swap is straightforward. The key difference is the breaking capacity — the 5SL3006-7 is rated 4.5 kA, while the 5SY6006-7 carries a higher rating. If the panel's fault-current study calls for more than 4.5 kA, the 5SL3006-7 won't be a drop-in replacement.

What compliance documentation does Siemens provide for 5SL3006-7?

The MCB is certified to IEC/EN 60898-1 and GB/T 10963.1. It's halogen-free and silicon-free. For RoHS, REACH, and UL documentation, contact your Siemens channel partner or distributor — those declarations are typically available on request.

MPN
5SL3006-7