Skip to main content
Siemens 5SL3110-6MB — 1-Pole MCB (DIN Rail)

Siemens 5SL3110-6MB SENTRON MCB, 1P B 10A 4.5kA

MPN5SL3110-6MB
Active

Siemens SENTRON 5SL3 series, miniature circuit breaker, 1-pole, B-curve, 10 A, 4.5 kA per EN 60898, 18 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SL3110-6MB — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityResidential buildings/infrastructure
5SL3110-6MB — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)4.5 kA
Overvoltage category3
5SL3110-6MB — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL3110-6MB — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL3110-6MB is a 1-pole SENTRON miniature circuit breaker with a B tripping characteristic, rated 10 A at 230/400 V AC and a 4.5 kA breaking capacity per EN 60898. The 18 mm width (one modular unit) snaps onto DIN rail, so it fits any standard distribution board or sub-panel without crowding adjacent ways.

Rated 10 A continuous at 230/400 V AC, single-phase or multi-phase. Overvoltage category 3 and pollution degree 2 confirm it's rated for fixed installations inside a panel, not for outdoor or harsh industrial environments. The mechanical endurance of 10 000 switching cycles is typical for an MCB in this class; it's not a switch-disconnector meant for daily load switching.

Sealable design allows lockout/tagout provisions. Halogen-free and silicon-free construction avoids corrosive off-gassing in enclosed panels.

Frequently asked questions

What is the breaking capacity of 5SL3110-6MB?

4.5 kA per EN 60898 at 400 V AC. That's the maximum prospective fault current it can safely interrupt.

How do I get pricing and availability for 5SL3110-6MB?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through our sourcing network.

Will 5SL3110-6MB fit a panel designed for 5SL3120-6MB?

Yes — same 18 mm width, same DIN-rail footprint, same SENTRON 5SL3 series. The only difference is the current rating (10 A vs 20 A) and the tripping characteristic (B vs C). No rewiring or panel modification needed.

MPN
5SL3110-6MB