Skip to main content
Siemens 5SL3116-6MB — 1-Pole MCB (DIN Rail)

Siemens 5SL3116-6MB SENTRON MCB, 1P B 16A 4.5kA

MPN5SL3116-6MB
Active

Siemens SENTRON 5SL3 series miniature circuit breaker, 1-pole, B characteristic, 16 A rated current, 4.5 kA breaking capacity per EN 60898, 230/400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL3116-6MB — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityResidential buildings/infrastructure
5SL3116-6MB — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)4.5 kA
Energy limitation classNo
Overvoltage categoryIII
5SL3116-6MB — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL3116-6MB — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SL3116-6MB — 1-pole B-curve MCB at 16 A

The Siemens SENTRON 5SL3116-6MB is a 1-pole miniature circuit breaker rated 16 A at AC with a B tripping characteristic and a 4.5 kA breaking capacity per EN 60898. It protects final circuits in residential and light commercial infrastructure where the B-curve's magnetic trip threshold (3 to 5 times In) suits resistive and general-purpose loads with modest inrush — think lighting, socket outlets, and small appliances rather than motor or transformer circuits that would call for a C or D curve. Rated operational voltage is 230/400 V AC single-phase / multi-phase, with a maximum of 250 V single-phase and 440 V multi-phase. The 4.5 kA rating per EN 60898 means it safely interrupts fault currents up to that level under the standard's test conditions — adequate for most residential and light commercial service-entrance panels where the prospective short-circuit current stays within that limit.

Mounting and integration

Occupies a single modular width unit (18 mm) on standard DIN rail. Depth is 76 mm, installation depth 70 mm. Mounting position is unrestricted — any orientation works. The IP20 rating applies with conductors connected, which is the standard for enclosed distribution boards; the breaker itself is not rated for exposed wet-area installation without an enclosure. Touch protection is built in per product feature. The housing is halogen-free and silicon-free, which matters when specifying for environments sensitive to outgassing — clean rooms, certain medical or data-center adjacent spaces.

Frequently asked questions

Will 5SL3116-6MB drop into a panel specified for 5SL3120-6MB?

Yes — both share the same 18 mm width, 76 mm depth, 70 mm installation depth, DIN-rail mounting, and SENTRON 5SL3 series footprint. The difference is the 16 A rating on this part versus 20 A on the 5SL3120-6MB. No rewiring needed if the circuit load is within 16 A.

MPN
5SL3116-6MB