Skip to main content
Siemens 5SL3206-6MB — 2-Pole MCB (DIN Rail)

Siemens SENTRON 5SL3206-6MB MCB, 2P B 6A 4.5kA

MPN5SL3206-6MB
Active

Siemens SENTRON miniature circuit breaker, 5SL3206-6MB, 2-pole, B-curve, 6 A rated, 4.5 kA breaking capacity per EN 60898, 400 V AC, 2 MW width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SL3206-6MB — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL3206-6MB — Electrical
ParameterValue
Number of poles2
5SL3206-6MB — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SL3206-6MB — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL3206-6MB — Environmental
ParameterValue
Pollution degree2
5SL3206-6MB — Specifications
ParameterValue
Energy Limitation Class3

Product details

The Siemens SENTRON 5SL3206-6MB is a 2-pole miniature circuit breaker rated 6 A with a B tripping characteristic, breaking 4.5 kA per EN 60898 at 400 V AC. The 2-pole design switches both line conductors simultaneously, with no neutral switching (the neutral conductor is not switched on this unit).

Panel fit and peer delta

The closest peer in the same SENTRON family is the 1-pole 5SL3116-6MB (16 A, B-curve, 1 MW width). The 5SL3206-6MB is physically wider (36 mm vs 18 mm) and rated lower (6 A vs 16 A) but carries the same 4.5 kA breaking capacity and 400 V AC rating. If your panel was laid out for the 5SL3116-6MB, the 5SL3206-6MB will not drop in without rewiring: the 2-pole unit needs two line conductors and occupies double the DIN space. The depth (76 mm) and height (90 mm) are identical, so the enclosure depth is not a constraint.

Installation and environmental limits

The sealable feature (tamper-evident seal wire) is present for applications requiring locked settings.

Frequently asked questions

What is the breaking capacity of 5SL3206-6MB?

4.5 kA per EN 60898 at 400 V AC. That is the maximum fault current it can safely interrupt under the standard.

Will 5SL3206-6MB fit in a panel designed for 5SL3116-6MB?

Not without changes. The 5SL3206-6MB is 2-pole (36 mm wide) versus the 1-pole 5SL3116-6MB (18 mm wide), so it needs double the DIN rail space and two line conductors. Depth and height match at 76 mm and 90 mm respectively.

Where can I buy 5SL3206-6MB?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SL3206-6MB