Siemens 5SL3216-7MB — 2-Pole MCB (DIN Rail)

Siemens 5SL3216-7MB SENTRON MCB, 2P C 16A 4.5kA 400V

MPN5SL3216-7MB
Active

Siemens SENTRON 5SL3216-7MB miniature circuit breaker, 2-pole, C-curve, 16 A, 4.5 kA at 400 V AC, 2 MW units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL3216-7MB — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL3216-7MB — Electrical
ParameterValue
Number of poles2
5SL3216-7MB — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL3216-7MB — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL3216-7MB — Environmental
ParameterValue
Pollution degree2
5SL3216-7MB — Specifications
ParameterValue
Energy Limitation Class3

Product details

The 5SL3216-7MB: The C-curve trips at 5–10× rated current, so it handles moderate inrush from small motors, transformers, or lighting ballasts without nuisance trips — standard for general-purpose branch circuits in residential and light-commercial panels. The 4.5 kA interrupting rating at 400 V AC is the fault current it can safely clear; verify the available fault current at the installation point does not exceed that. The 2-pole construction switches both line conductors, suited for 230/400 V single-phase or two-phase loads where full isolation is needed.

Occupies 2 modular width units (36 mm) on standard 35 mm DIN rail. Depth 76 mm, height 90 mm, installation depth 70 mm. Mounting position any; sealable for tamper-proof applications. Halogen-free and silicon-free construction — suitable for environments with sensitive electronics or strict fire-load requirements.

Rated per EN 60898 for breaking capacity. Overvoltage category III, degree of pollution 2. Energy limitation class 3. Touch protection provided. Suitable for residential buildings and infrastructure installations per the manufacturer's designation.

Frequently asked questions

What is the breaking capacity of 5SL3216-7MB?

The 5SL3216-7MB has a 4.5 kA breaking capacity at 400 V AC per EN 60898.

How do I get pricing and availability for 5SL3216-7MB?

Submit an RFQ for the 5SL3216-7MB through the storefront; current pricing and availability are confirmed at quote time through independent distribution channels.

What is the difference between 5SL3216-7MB and 5SL6016-7KL?

The 5SL6016-7KL is a 1P+N (switched neutral) variant with a 6 kA breaking capacity at 230 V AC, versus the 5SL3216-7MB's 2-pole (both poles switched) 4.5 kA at 400 V AC. The 5SL6016-7KL occupies 1 MW unit (18 mm) versus the 5SL3216-7MB's 2 MW units (36 mm). Both are 16 A C-curve SENTRON breakers with the same 76 mm depth and 90 mm height.

Will 5SL3216-7MB drop into a panel specified for 5SL6016-7KL?

No — the 5SL3216-7MB is 36 mm wide (2 MW units) while the 5SL6016-7KL is 18 mm wide (1 MW unit). The panel would need the wider slot and both line conductors wired through the breaker.

MPN
5SL3216-7MB